User Manual - QG65N2 SAE J1939 Inclinometer (Type JB) V1.1
4.4.
CAN termination
A CAN bus should be terminated properly to prevent signal reflections. The QG65N2 J1939 Inclinometer has an
internal 120 Ohm termination resistor. By default, this is disabled.
A separate M12 termination resistor and T-connector are also available as accessories.
Figure 5 - M12 CAN terminator male 5p.
Order code: 10217
Figure 6 - M12 CAN terminator female 5p.
Order code: 10194
Figure 7 - M12 T-connector 5p.
Order code: 11822
The advantage of using a separate termination plug instead of the internal termination resistor is that an external
termination plug is clearly visible. This helps to prevent an inadvertent double termination that could cause the
entire CAN bus to malfunction.
5.
Technical data
Please refer to the datasheet of your product.