Operating Instructions

Always split the log along the grain of the wood. Splitting across 

the grain may cause some types of wood to burst or splinter 

resulting in possible injury.

If a log becomes stuck on the wedge, remove both hands, unplug 

the log splitter from the power source and knock the log off of 

the wedge with a hammer.  Do not attempt to dislodge the log 

with your hands.

When finished splitting the logs, switch the motor off and 

unplug the power cable.

DIRECTIONS FOR REPLACING HYDRAULIC FLUID

1) Place a large pan under the motor end of the log splitter.

2)  Use the included hex wrench to loosen the fluid drain bolt and 

remove the bolt with the attached dipstick.

3)  Raise the motor end of the log splitter to allow the fluid to drain 

in to a pan. Lower the splitter when it is empty. (See Fig A.)

4) Dispose of the used fluid properly.

5)  Raise the splitting wedge end of the splitter and make sure it is 

secure. 

6)  Pour approximately 3.2 liters of approved hydraulic fluid into 

the tank.

7)  Check the fluid level of the dipstick. Add more fluid if needed. 

(See Fig B.)

8) Replace the fluid drain bolt and tighten securely.

9) Lower the log splitter.

STORAGE

Store the log splitter switched off and unplugged. Allow the log 

splitter to cool for 5 minutes after use before storing. Protect 

the power supply cable from heat, sunshine, aggressive liquids 

and sharp edges. Store unit in a clean, dry area. Don’t store it 

unprotected outdoors, next to corrosive materials or in a damp 

environment. 

14

!

WARNING

1004

77

Fig. A

Fig. B

Содержание 100481

Страница 1: ...g Splitter This safety alert symbol identifies important safety messages in this manual Failure to follow this important safety information may result in serious injury or death MODEL 100481 Operation...

Страница 2: ...1100 W 120th Ave Suite 600 Westminster CO 80234 720 287 5182 For Service or Questions Call 1 877 487 8275 720 287 5182 www dirtyhandtools com Dirty Hand Tools is a brand of...

Страница 3: ...y Decals 5 Operation 6 Preparation of the Log 6 Work Area 6 Operation of the Log Splitter 6 Repair and Maintenance 7 Hydraulic Safety 7 Fire Prevention 9 Transportation 9 Assembly Instructions 10 Oper...

Страница 4: ...any questions or concerns about the safe operation of this equipment INTENDED USE Do Not Use the log splitter for any purpose other than splitting wood for which it was designed Any other use is unaut...

Страница 5: ...mum of 10 feet away from the work area when operating this log splitter Only the operator is to be near the log splitter during use Do not operate the log splitter when under the influence of alcohol...

Страница 6: ...te the log splitter in daylight or under good artificial light Keep the work area free of clutter Remove split wood from around the log splitter immediately after each use to avoid potential tripping...

Страница 7: ...control handle ALWAYS check for damaged parts before operation Do not operate until it is repaired Do not use an extension cord longer than 25 feet Minimum cord gage must be 16 An undersized cord will...

Страница 8: ...n along with the mechanical parts Be sure to replace frayed kinked cracked or otherwise damaged hydraulic hoses or hydraulic components Check for hydraulic fluid leaks by passing a piece of paper or c...

Страница 9: ...his log splitter in dry areas as a precautionary measure against possible flying sparks TRANSPORTATION DO NOT move this log splitter while the motor is running DO NOT carry any cargo or wood on the lo...

Страница 10: ...air or replacement of parts Remove the log splitter from the shipping container Inspect it for shipping damage If anything is damaged contact your dealer or carrier 1 2 3 4 8 7 12 11 9 10 5 6 Front Vi...

Страница 11: ...properly Do not operate this log splitter if you have doubts or questions concerning safe operation Call our customer service department at 720 287 5182 1 877 487 8275 or visit www dirtyhandtools com...

Страница 12: ...while the log splitter is in use Close the bleed screw after operation Make sure that the bleed screw is closed before and during moving Hydraulic fluid may leak through the bleed screw opening if th...

Страница 13: ...tage and frequency match the data stated on the model plate 6 Plug in the power cable and switch on the motor NEVER use an extension cord longer than 25 feet Minimum cord gauge must be 16 The power su...

Страница 14: ...e attached dipstick 3 Raise the motor end of the log splitter to allow the fluid to drain in to a pan Lower the splitter when it is empty See Fig A 4 Dispose of the used fluid properly 5 Raise the spl...

Страница 15: ...y be air in the system or insufficient hydraulic oil Check the level of the hydraulic oil with the dipstick 6 For other hydraulic and motor problems not addressed in this manual please contact a quali...

Страница 16: ...ace of Purchase Specifications SKU Part No 100481 Description Horizontal Log Splitter Maximum Splitting Force 5 Tons Motor 120V 60Hz 15A 2HP 3 400 RPM Hydraulic Capacity 2 8 quarts Power Cord 6 ft gro...