Specification 

MODEL 

 

 

Vesta Pro 1000 

Vesta Pro 1400 

Vesta Pro 2000 

CAPACITY 

VA/W 

1000VA/600W 

1400VA/840W 

2000VA/1200W 

INPUT 

Voltage 

120VAC 

 

Voltage Range 

89-145VAC 

OUTPUT 

Voltage 

120VAC 

 

Voltage 
Regulation 
(Battery Mode) 

±

10% 

 

Frequency 

50Hz or 60Hz 

 

Frequency 
Regulation 
(Battery Mode) 

+/-1 Hz 

 

Output Waveform 

Stepped Sine-wave

 

BATTERY 

Battery Type and 
Number* 

12V/7AH x 2pcs 

12V/9AH x 2pcs 

 

Back up Time (at 
a PC load with 
15" monitor) 

40

 minutes 

45

 minutes 

 

Recharge Time 

10 Hours to 90% 

6 hours to 90% 

TRANSFER 
TIME 

Typical 

4-8ms 

INDICATOR 

LCD Display 
Models 

The LCD will always turn on when UPS work, Including in off 

charging mode and fault mode 

AUDIBLE 
ALARM 

Battery Mode 

Sounding every 10 seconds 

Low Battery 

Sounding every second 

Overload 

Sounding every 0.5 second 

Battery Replace 

Sounding every 2 seconds 

Fault 

Continuously sounding 

PROTECTION 

Full Protection 

Discharge, Overcharge, Short Circuit and Overload 

Protection 

PHYSICAL 

Dimension, 
DxWxH (mm) 

15.9 x 8.1 x 5.7in 

Net Weight (kgs) 

21.4lbs 

26.5lbs 

ENVIRONMENT 

Operating 
Environment 

0- 40°C, 0-90 % Relative Humidity (non-condensing) 

Noise Level 

Less than 45dB

 

Less than 50dB

 

* Product specifications are subject to change without further notice. 

 

 

Содержание vesta pro 1000 vac

Страница 1: ......

Страница 2: ......

Страница 3: ... position and disconnect the power cord form the AC power supply to properly disable the UPS Do not allow any liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit This unit intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in lo...

Страница 4: ...arts on the top of batteries 5 Disconnect charging source prior to connecting or disconnecting batteries terminal Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing batteries replace with the same number of the sealed lead acid batteries This pluggable type A eq...

Страница 5: ...System Description Front Panel 1 LCD Back Light 2 Power ON OFF Switch Back Panel 1 Communication Port 2 Cooling Fan 3 AC Output 4 Modem Phone Line Surge Protection 5 Circuit Breaker 6 AC Input ...

Страница 6: ...all the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Do not operate your UPS in an environment where the ambient temperature or humidity is high On the other hand place the UPS unit away from monitor at least 20cm to avoid interference 3 Charging This unit is shipped from the factory...

Страница 7: ...back of the UPS maximum of three devices 5 Modem Phoneline Connection Plug incoming internet line into the In socket at the back of the UPS Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the UPS Plug the other end to the modem input socket as shown ...

Страница 8: ...unit press the power switch again When Swith ON The LED lighting 7 LCD Display Specification The LED will always turns on when UPS works including in off charging mode and fault mode When LCD start to work it will display all information for 3s a When in normal mode it will display as below ...

Страница 9: ...ery mode it will display as below And the mark will flicker every 1second Note If I P V 20V input voltage will display 000 d When in off charging mode it will display as below Note the output voltage always is displayed as 000 in off charging mode e When in fault mode it will display as below FAULT ...

Страница 10: ...character and the reason of fault only ...

Страница 11: ... 100 7 Battery capacity definition Battery LEVEL Battery bar Indication Battery voltage 11V 11V Battery voltage 11 5V 11 5V Battery voltage 12 5V Battery voltage 12 5V 8 When over load the mark will flicker every 1second 9 When battery low the mark will flicker every 1second ...

Страница 12: ...failure With this software users can monitor and control any UPS on the same LAN no matter how far from the UPSs Installation procedure 1 Go to the website http www ups software download com index htm 2 Choose the operation system you need and follow the instruction described on the website to download the software 3 When downloading all required files from the internet enter the serial No 511C1 0...

Страница 13: ...Verify that the load matches the UPS capability specified in the specs When power failure back up time is shorten 1 Overload of the UPS 1 Remove some noncritical load 2 Battery voltage is too low 2 Charge battery 10 hours or more 3 Battery defect due to high temperature operation environment or improper operation to battery 3 Replace with the same type of battery Communication lost between UPS and...

Страница 14: ...ANSFER TIME Typical 4 8ms INDICATOR LCD Display Models The LCD will always turn on when UPS work Including in off charging mode and fault mode AUDIBLE ALARM Battery Mode Sounding every 10 seconds Low Battery Sounding every second Overload Sounding every 0 5 second Battery Replace Sounding every 2 seconds Fault Continuously sounding PROTECTION Full Protection Discharge Overcharge Short Circuit and ...

Отзывы: