CHAPTER 4: Operation

State

The status of the Dante  module is monitored by a 
LED at the front.

STATE

LED blue - indicates the state of the 
Dante module.

 (OFF)

 

=

  module not available

 (ON)

 

=

  module is working

    (blinking)

 

=

  module in failsafe mode*

* The Dante module starts into failsafe mode if its  
  fi rmware is corrupted. This may happen in very rare  
  cases only. Should you encounter this state, please  
  contact support for further information.

Содержание EXBOX.MD

Страница 1: ...EXBOX MD User s Manual Version 1 0...

Страница 2: ...anteed that all product names products trademarks requisitions regulations guidelines speci cations and norms are free from trade mark rights of third parties All entries in this document have been th...

Страница 3: ...t works 9 CHAPTER 2 Legal issues facts 10 Before Installing This Device 10 First Aid in case of electric shock 11 Defective Parts Modules 12 Updates 12 Intended Operation 13 Conditions of Warranty 14...

Страница 4: ...te Clocking 34 Sample Rate 36 State 38 CHAPTER 5 Remote Control 39 Dante Controller 39 EXBOX MD Remote 46 CHAPTER 6 Troubleshooting and Maintenance 49 Troubleshooting 49 Maintenance 51 CHAPTER 7 Techn...

Страница 5: ...l or Index Directory at the end of the document to locate help on a particular topic You can access more information and latest news by visiting on the DirectOut website at www directout eu Convention...

Страница 6: ...ith three MADI ports and four network ports it offers straight forward conversion of 64 audio channels between MADI and Dante Interfaces 3 MADI I Os 4 Network ports 3 standard 1 PoE The built in netwo...

Страница 7: ...RJ45 1 Gbit s PoE Number of streams 32 Number of channels 64 1 FS 32 2 FS 16 4 FS Network Standards Dante AES67 Modes Switched or Redundancy Remote Dante Controller EXBOX MD Remote MADI Formats 56 64...

Страница 8: ...an easy to use frontend for bidirectional signal exchange between Dante and MADI environments Typical applications include Integration of MADI in Dante setups Redundant recording setups using MADI and...

Страница 9: ...ow it works Each MADI port and the Dante input can be selected as source for any output The network audio is controlled via the Dante Controller software provided by Audinate SFP BNC SC Dante SFP BNC...

Страница 10: ...ately by pulling out the power lead All devices must be grounded The device is grounded through its IEC power connections All devices must be connected to the mains using the three cord power leads su...

Страница 11: ...person as quickly as possible from the electric power source as follows Switch off the equipment Unplug or disconnect the mains cable Move the person away from the power source by using dry insulatin...

Страница 12: ...ther with a detailed description of the fault We would like to remind you to please check carefully whether the failure is caused by erroneous con guration operation or connection before sending parts...

Страница 13: ...is unit other than for the intended use described above Consecutive damages are also excluded explicitly The general terms and conditions of business of DirectOut GmbH are applied Intended Operation E...

Страница 14: ...ut GmbH over the period of 36 months for all components that are essential for proper and intended operation of the device The date of purchase is applied for this period Consumable parts e g battery...

Страница 15: ...stances This device was constructed ful lling the directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment 2002 95 EC WEEE Directive on Waste Elec...

Страница 16: ...0 EXBOX MD Manual Version 1 0 CHAPTER 2 Legal issues facts Contact DirectOut GmbH Leipziger Str 32 09648 Mittweida Germany Phone 49 0 3727 5665 100 Fax 49 0 3727 5665 101 Mail sales directout eu www d...

Страница 17: ...Legal issues facts Contents The contents of your EXBOX MD package include 1 x EXBOX MD 1 x external power supply unit 9 24 V 1 x Manual To complete the delivery download the Dante Controller software...

Страница 18: ...eiver with LC connectors No DOICT0130 Specification of the optical SFP modules SFP Multimode Singlemode Wavelength TX 1310 nm 1310 nm Wavelength RX 1310 nm 1310 nm Distance 2 km 10 km Powerbudget dB 1...

Страница 19: ...1360 nm Wavelength RX min 1260 nm 1260 nm Wavelength RX max 1620 nm 1600 nm Transmit min 19 00 dBm 9 00 dBm Transmit max 14 00 dBm 3 00 dBm Receive min 30 dBm 21 00 dBm Receive max Receiver overload...

Страница 20: ...page 20 of 60 EXBOX MD Manual Version 1 0 CHAPTER 2 Legal issues facts BOX MOUNT XL for optimal rack mount of up to three devices in a 19 frame No DOAPA0886 three devices in a 19 frame No DOAPA0886...

Страница 21: ...cient air circulation for cooling WARNING The synthetics of the delivered pads might cause stains on damageable surfaces To avoid staining of furniture surfaces it is recommended to place a protective...

Страница 22: ...Installation Retain the protective cap if the optical port is unused This will protect against soiling which can lead to malfunction 3 Remove the protective cap from the optical MADI port s before use...

Страница 23: ...ate network cables CAT5E or better For larger setups an ethernet switch may become necessary Recommended features for use with Dante Managed Gigabit switch Quality of Service QoS with four queues Diff...

Страница 24: ...r supply unit Additional power supply units are available from your local DirectOut representative The external power supply must be connected to the mains using the three cord power leads supplied wi...

Страница 25: ...device should it need to be dispatched for service Never connect a PoE link to a network interface that is not marked explictly for PoE operation The voltage supplied there may damage the interface WA...

Страница 26: ...page 26 of 60 EXBOX BLDS Manual Version 1 3 Chapter 3 Installation This page is left blank intentionally...

Страница 27: ...basic operation of the device Note that throughout this manual the abbreviation FS refers to sample rate or sample frequency So when dealing with scaling factors the following sample rates can be wri...

Страница 28: ...lied there may damage the interface Global Control PSU 1 Hirose socket Connect the power supply here 9 24 V DC PSU 2 Hirose socket Connect the power supply here 9 24 V DC 01 PoE RJ45 socket Connect Po...

Страница 29: ...page 29 of 60 EXBOX MD Manual Version 1 0 CHAPTER 4 Operation POWER PSU 1 PSU 2 PoE LED green indicates state of power supply OFF power supply not working ON power supply working...

Страница 30: ...page 30 of 60 EXBOX BLDS Manual Version 1 3 CHAPTER 4 Operation This page is left blank intentionally...

Страница 31: ...conversion between different MADI formats is possible MADI BNC OUT BNC socket MADI output connect here for MADI output signal MADI BNC IN BNC socket MADI input connect MADI input signal here MADI SC...

Страница 32: ...ual operation redundant two ports primary secondary The switch will be con gured automatically by selecting the respective operation mode in Dante Controller With redundant operation each two interfac...

Страница 33: ...rk interface connect here for network transmission 04 RJ45 socket 1 Gbit s Network interface connect here for network transmission LED left Port 1 to 4 LED orange indicates the link state of the netwo...

Страница 34: ...1588 2002 PTPv1 or v2 in AES67 mode MADI input internal clock generator CLOCK SOURCE SYNC SFP BNC SC PTP INT LED RGB indicates selected clock source and the lock sync state of MADI input PTP clock or...

Страница 35: ...nate PTP sync is handled by the Dante network automatically EXBOX MD can act as a PTP slave or Grandmaster preferred master When clocking to a source other than PTP make sure to enable the Enable Sync...

Страница 36: ...e rate 44 1 kHz 48 kHz and the scaling factor 1 FS 2 FS 4 FS is displayed by four leds at the front panel NOTE At higher sample rates the number of audio channels is reduced depending on the integer o...

Страница 37: ...is used SAMPLE RATE 48k LED green indicates the base rate of the audio engine OFF base rate is different from 48 kHz ON base rate of 48 kHz or multiple of is used SAMPLE RATE 2 FS LED yellow indicates...

Страница 38: ...front STATE LED blue indicates the state of the Dante module OFF module not available ON module is working blinking module in failsafe mode The Dante module starts into failsafe mode if its rmware is...

Страница 39: ...software dante controller A detailed documentation about using Dante Controller is available here https dev audinate com GA dante controller userguide webhelp At startup Dante Controller scans the ne...

Страница 40: ...iew is organised in several tabs All detected Dante devices are shown on a list EXBOX MD is delivered with the network interface set to DHCP as a default Dante Controller can be used to discover the d...

Страница 41: ...forms about the clock settings of each connected device and allows to modify them Preferred Master sets the device as PTP Grandmaster in the network Enable Sync to External allows to clock the device...

Страница 42: ...cessible in the tab Routing Dante Receivers in the vertical column displays the receiving devices destinations Dante Transmitters in the horizontal row displays the transmitting devices sources The ch...

Страница 43: ...ised in to several tabs It can be opened by double clicking on to a device name in the Network View The status tab informs about the current rmware and software versions TIP To update your device the...

Страница 44: ...XBOX MD Manual Version 1 0 CHAPTER 5 Remote Control Network Config The tab Network Con g of the device view provides access to the operating mode of the built in network switch and the network setting...

Страница 45: ...ontrol Device Config The tab Device Con g to adjust the device name sample rate encoding modes and more The clock source of the EXBOX MD is con gured in the web control of the EXBOX MD Open a browser...

Страница 46: ...Remote Control EXBOX MD Remote Some device speci c parameters are controlled via a website Clock source Scaling factor of base sample rate Audio signal routing The remote control is accessible via a b...

Страница 47: ...blinking red signal lock not in sync with selected clock source blinking green input selected as clock source and no signal lock Clock master Pull down menu selection of clock source Values PTP PTP c...

Страница 48: ...Manual Version 1 0 CHAPTER 5 Remote Control ROUTING ROUTING SFP BNC SC Dante Pull down menu selection of signal source of each signal output Values SFP MADI SFP input BNC MADI BNC input SC MADI SC inp...

Страница 49: ...nd Maintenance Issue Possible reason Solution Device doesn t work Power supply is broken Check that the power supply switch is on that the device is connected to the power supply and that the socket i...

Страница 50: ...o signal at the output port Connectors of the signal cable are dirty Use an air supply to carefully remove any dust Never use objects for cleaning or Exchange the signal cable MADI signal at the input...

Страница 51: ...1 0 CHAPTER 6 Troubleshooting and Maintenance Maintenance To clean the device use a soft dry cloth To protect the surface avoid using cleaning agents The device should be disconnected from the power s...

Страница 52: ...Height 42 mm Depth 146 mm Weight 0 7 kg Power Consumption 9 W typical Power Supply 2 x Hirose socket HR10 9 V 24 V DC external WARNING The connected power supply must provide a current limiting to a m...

Страница 53: ...ISO IEC 9314 3 Wave length 1310 nm Multi Mode 62 5 125 or 50 125 MADI Ports BNC coaxial BNC socket input output Impedance 75 0 3 V up to 0 6 V peak to peak MADI Ports SFP empty cage without module Sa...

Страница 54: ...a Network 4 x RJ45 socket Gigabit Ethernet for transmission of network audio control data and firmware updates Network Layer 3 32 streams 64 channels I O 1 FS 32 2FS 16 4FS Standard Dante AES67 Brookl...

Страница 55: ...Appendix A Wiring Sketches Appendix A Wiring Sketches Hirose HR10 DC PSU Pin Signal 1 DC 2 DC 3 DC 4 DC NOTE To ensure proper operation all pins should be connected NOTE Ground is connected with the c...

Страница 56: ...5 Conformity Certi cates CE 15 RoHS 15 WEEE 15 Contact 16 Contents 17 Conventions 5 D Dante module state 38 Defective Parts Modules 12 Dimensions 52 E Environmental conditions 21 52 Ethernet switch 23...

Страница 57: ...ge 57 of 60 EXBOX MD Manual Version 1 0 Index S Sample rates 7 Scaling Factor 27 SFP Modules 18 Sketch Hirose HR10 DC PSU 55 Support 49 T Technical data 52 Troubleshooting 49 U Updates 12 W Warranty 1...

Страница 58: ...page 58 of 60 EXBOX MD Manual Version 1 0 Notes...

Страница 59: ...page 59 of 60 EXBOX MD Manual Version 1 0 Notes...

Страница 60: ...DirectOut GmbH T 49 3727 5665 100 F 49 3727 5665 101 www directout eu Leipziger Strasse 32 09648 Mittweida Germany...

Отзывы: