16
© 2012 Directed. All rights reserved.
Bitwriter - Only Options
If programming with the Bitwriter®, the learn routine can be locked or unlocked. If the learn routine has previously been locked, it must
be unlocked with Bitwriter® - this cannot be done manually with the control center button.
The Bitwriter®
gives you access to a wider range of system options. These features and the adjustments that may be programmed are
described in the table below.
Menu
Item
Feature
Default
Options
1
Siren Duration
30 sec.
1-180 sec.
2
Aux 2 Timed Output
30 sec.
1-90 sec.
3
Aux 3 Timed Output
30 sec.
1-90 sec.
4
Aux 4 Timed Output
30 sec.
1-90 sec.
5
Engine Runtime
12 min.
1-60 min.
6
Diesel Start Delay
15 sec.
1-90 sec.
7
Timer Mode Runtime
12 min.
1-16 min.
8
Virtual Tach Fine Tune
Not initialized
0-1000 in 50 millisecond increments
9
Transmitter Programming
Unlocked
Locked
10
Feature Programming
Unlocked
Locked
Note:
The “Zap” feature on the Bitwriter does not reset the Virtual tach or security features enabled/disabled settings
Bitwriter feature descriptions
1. Siren duration
:
Sets the siren output for full trigger activations from 1-180 seconds.
2. Aux 2 timed output:
Sets the output duration in 1 second intervals up to 90 seconds.
3. Aux 3 timed output
:
Sets the output duration in 1 second intervals up to 90 seconds.
4. Aux 4 timed output:
Sets the output duration in 1 second intervals up to 90 seconds.
5. Engine runtime:
Sets engine runtime during normal remote start operations from 1-60 minutes.
6. Diesel start delay:
Sets the delay before engine crank in 1 second intervals from 1- 90 seconds for diesel engine vehicles.
7. Timer mode runtime:
Sets the duration of runtime when the engine is started by the Timer Mode from 1-16 minutes.
8. Virtual tach fine tune:
Adds or subtracts crank time in VirtualTach mode in order to overcome engine types that short crank or over-crank on the first start attempt.
9. Transmitter programming:
Locks and unlocks the user’s ability to enter the remote control/Reset menu and manually change any functions using the Control Center
10. Feature Programming:
Locks and unlocks the user’s ability to enter the feature menus and manually change the main unit programming using the Control Center.