Programming System Features

The System Features Learn Routine dictates how the unit operates. It is possible to access and change most of the 

feature settings using the Valet  button. 

1. 

Turn

 the ignition on, then off. 

2. 

Select

 a Menu. Within 10 seconds, 

Press

 and 

hold

 the Valet button. The number of LED flashes and horn 

honks indicates the menu number. A single LED flash and honk indicates menu 1. Two LED flashes and 2 

honks indicates menu 2. 

3.  When the desired menu LED flashes and honks are heard, 

release

 the Valet  button.

4. 

Select

 a Feature, within 10 seconds. 

Press

 and 

release

 the Valet button the number of times correspond-

ing to the feature you wish to change. Then 

press

 and 

hold

 one more time to select the feature. The LED 

flashes and the horn honks to indicate which feature is selected.

5. 

Program

 the Feature. While holding the Valet  button, you can program the feature using the remote 

control. 

Pressing the button on the remote control advances to each feature option. The LED flashes and the horn honks 

indicating which option is selected. 

Once a feature is programmed:

• 

Other features can be programmed within the same menu

• 

Another menu can be selected

• 

The learn routine can be exited if programming is complete

To access another feature in the same menu:

1. 

Press

 and 

release

 the Valet  button the number of times necessary to advance from the feature you just pro-

grammed to the next one you want to program.

2.  Then 

press

 the Valet button once more and 

hold

 it. 

To select another menu:

1. 

Press

 and 

hold

 the Valet  button.

2.  After 3 seconds, the unit advances to the next menu, the horn honks and LED flashes indicating which menu 

has been accessed.

The learn routine exits if any of the following occurs:

• 

The ignition is turned On

• 

There is no activity for 30 seconds

• 

The Valet  button is pressed too many times

Bitwriter - Only Options

If programming with the Bitwriter®, the learn routine can be locked or unlocked. If the learn routine has 

previously been locked, it must be unlocked with Bitwriter® - this cannot be done manually with the Valet  

button.

The Bitwriter® 

 gives you access to a wider range of system options.  These additional features and the adjust-

ments that may be programmed are described in the table below.  

Menu Item 

Feature

Default

Options

1

Engine Runtime

12 min.

1-60 min.

2

Diesel start type

Off

Timed

3

Diesel start delay time (seconds)

15 sec

1-90 sec.

4

Virtual Tach Fine Tune

Not initialized

0 to 1 second in 50 millisecond 
increments

5

Remote control programming

Unlocked

Locked

6

Feature Programming

Unlocked

Locked

Feature Menus

Default settings are in 

bold

 type. 

Menu 1 

Feature # 

Feature

Opt. 1

Opt. 2

Opt. 3

Opt.4

Opt. 5+

1

Horn function 

Off

Siren 

20 mS

Siren 

30 mS

Siren 

40 mS

Siren 

50 mS

2

Ignition con-

trolled lock

On

Off

3

Ignition con-

trolled unlock  

On

Off

4

Doorlock out-

put duration

0.8 sec.

3.5 sec.

0.4 sec.

5

Double pulse 

unlock

Off

On

6

Double pulse 

lock

Off

On

7

Factory Alarm 

Disarm func-

tion

with unlock

Before unlock  Remote start 

only

8

Factory Alarm 

Disarm Pulses

Single

Double

9

Comfort* 

Closure

Comfort 

Closure 1

Off

Comfort 

Closure 2

10

Panic*

On

Off

*Option not available on 1- button

Menu 2 

Feature # 

Feature

Opt. 1

Opt. 2

Opt. 3

Opt.4

Opt. 5+

1

Engine check-

ing

Virtual tach

voltage

Off

tachometer

2

Engine 

Runtime

12 min

24 min

60 min

3

Park light 

output

Pulsed

Constant

4

Cranking time

0.6 sec.

0.8 sec.

1.0 sec.

1.2 sec.

1.4, 

1.6, 

1.8, 

2.0, 

4.0 sec

5

Activation 

pulse count 

1 pulse

2 pulses

3 pulses

6

2nd Ignition 

behavior

Ignition

Accessory 

7

Accessory 

output 

Off during 

wait-to-start

On during 

wait-to-start

8

2nd Status 

behavior

Normal

Latch rear 

defogger

Pulse rear 

defogger

9

Anti-grind 

On

Off

10

Diesel start 

delay

Off

Timed 15 sec

Timed 30 sec. Timed 45 sec.

11

Timer mode-

run time *

12 min

3 min

6 min

9 min

*Option not available on 1- button

Remote Programming

1.  Turn key to the ON position

2.  Within 10 seconds, press and release Valet button one time.

3.  Within 10 seconds, press and hold the Valet button. The LED will flash one time and the horn honks (if con-

nected) to confirm entry into remote programming. Do not release the valet button.

4.  Press the button on the remote control. The horn honks to confirm the remote has been programmed.

5.  Release the Valet  button. 

6.  Turn the key to the Off position. The horn sounds one long honk to confirm that remote programming has 

been exited.

The programming routine exits if any of the following occurs:

• 

The ignition is turned off

• 

There is no activity for 30 seconds

• 

The Valet  button is pressed too many times

 

Basic Remote Functions

Button Press

Function when remote 

start is OFF

Function when remote 

start is ON

Press for less than 1.5 seconds

Start the engine

Unlock doors

Press for more than 1.5 seconds Car finder

Stop the engine

Reset and Deletion

If a feature/virtual tach needs to be reset or the remote controls need to be deleted, use the following procedure.

1.  Turn the ignition to the ON position (The heavy gauge pink wire must be connected).

2.  Within 10 seconds, press and release the Valet  button: 2 times if you want to delete remotes, 3 times to 

reset features or 4 times to reset virtual tach. These features are described next. 

Delete remotes:

 This feature erases all remotes from the memory of the system. This is useful in cases 

when a customer’s remote is lost or stolen.

Note: This does not reset the programmed features of the  system or reset the Virtual Tach setting.  

 

Reset Features:

 This resets all features of the  system to the factory default settings. 

Note: This feature does not delete the remotes from the  system or reset the Virtual Tach setting  

 

Virtual Tach Reset:

 Deletes all previously learned values for Virtual Tach, and on the next remote start 

sequence the unit begins virtual tach initialization.

Note: The “Zap” feature on the Bitwriter does not reset the Virtual tach setting.

3.  Once you have selected the function step, press the Valet  button  once more and hold it. The LED flashes and 

the horn honks to confirm the selected functional step. Do not release the Valet  button.

4.  While holding the Valet  button, press the button on the remote control. The horn honks to confirm that the 

feature has been successfully reset. You can now release the Valet button. 

Additional information can be 

found at: 

www.directechs.com

 

Отзывы: