![Directed Electronics Clifford 20.7X Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/directed-electronics/clifford-20-7x/clifford-20-7x_installation-manual_2507173017.webp)
17
© 2009 Directed Electronics. All rights reserved.
Off: the Door lock and Factory Alarm Re-arm outputs will maintain the current status (locked/un-
1.
locked) during remote start and after shut down
On: the Door lock and Factory Alarm Re-arm outputs will arm/lock the vehicle during remote start
2.
and after shutdown
Bitwriter - Only Options
If programming with the Bitwriter®, the learn routine can be locked or unlocked. If the learn routine
has previously been locked, it must be unlocked with Bitwriter® - this cannot be done manually with
the Control button.
The Bitwriter®
gives you access to a wider range of system options. These features and the adjustments
that may be programmed are described in the table below.
Menu
Item
Feature
Default
Opt. 2
Opt. 3
Opt.4
Opt. 5+
1
Aux/Trunk Icon Type*
Trunk
Window
Sunroof
Audio
Lights/Left dr/Right dr/Rear Hatch
2
Aux 1 Timed Output
30 sec.
Options: 1 to 90 sec.
3
Aux 1 Icon Type*
Pulsed
Trunk
Window
Sunroof
Audio/Lights/Left dr/Right dr/Rear Hatch/
Timed/Latched
4
Aux 2 Timed Output
30 sec.
Options: 1 to 90 sec.
5
Aux 2 Icon Type*
Pulsed
Trunk
Window
Sunroof
Audio/Lights/Left dr/Right dr/Rear Hatch/
Timed/Latched
6
Aux 3 Timed Output
30 sec.
Options: 1 to 90 sec.
7
Aux 3 Icon Type*
Pulsed
Trunk
Window
Sunroof
Audio/Lights/Left dr/Right dr/Rear Hatch/
Timed/Latched
8
Aux 4 Timed Output
30 sec.
Options: 1 to 90 sec.
9
Diesel Start Delay
type (seconds)
15 sec.
Options: 1 to 90 sec.
10
Timer Mode Runtime
(minutes)
12 min.
Options: 1 to 16 min.
11
Timer Mode Starts
6 starts
Options: 1/2/3/4 to
24 (Starts) in increments of 2
12
Timer mode intervals
(hours)
3 hr.
Options: 1/2/
3
/4 to 24 in 2 hour increments
13
Smart start low temp
0° (F)
Options: OFF, -20° to 70° in 10° increments
14
Smart start high temp
100° (F)
Options: OFF, 40° to 130° in 10° increments
15
Smart start low bat-
tery (volts)
10.5V
Options: OFF, 9V to 12.5V in 0.5V increments
16
Starter Release Fine
Tune
6
(normal)
Options: 0 to 20 in increments of 1
17
Feature Programming
Unlocked
Locked
18
Transmitter Program-
ming
Unlocked
Locked
19
Remote Start Runtime
12 min.
Options: 1 to 60 min.
20
Virtual Tach Fine Tune
Not Ini-
tialized
Options: Not initialized, 0 to 1000 in 50 millisecond increments
* Not available on 1-way remote