Warnings

 

WARNING: Risk of Serious Injury or Death. These products are intended only for use with 

the Direct Supply Panacea 1000 Adjustable-Height Low bed. Never use these products on any 
other bed; the use of this product with any other bed could result in an unproven or unsafe 
configuration, potentially resulting in serious injury or death. 

 

WARNING: Risk of Serious Injury or Death. Use a properly sized mattress in order to 

minimize the gap between the side of the mattress and the Direct Supply Panacea assist device 
or siderail. This gap must be small enough to prevent a resident from getting his/her head or 
neck caught in this location. Make sure that raising or lowering the bed, or adjusting the sleep 
surface, does not create hazardous gaps. Failure to do so could result in serious injury or 
death.

 

WARNING: Risk of Serious Injury or Death. Properly locate the mounting brackets. The gap 

between the head/foot panel and the Direct Supply Panacea assist device or siderail must be 
small enough to prevent a resident from getting his/her head or neck caught in this location 
(see the installation instructions for more information, if applicable). If multiple assist devices 
are needed, position them such that the gap between them is large enough that the trunk and 
hips can easily pass through. Make sure that raising or lowering the bed, or adjusting the sleep 
surface, does not create hazardous gaps. Direct Supply Panacea assist devices or siderails should 
not be used if ANY openings within the bed system allow a resident to get his/her head or neck 
lodged within these openings. Failure to do so could result in serious injury or death.

 

WARNING: Risk of Serious Injury or Death. Do not use the Direct Supply Panacea assist 

device as an assist until you have verified that it is up AND locked. Injury to resident or 
caregiver may result if this procedure is not followed.

 

WARNING: An optimal bed system assessment should be conducted on each resident 

by a qualified clinician or medical provider to ensure maximum safety of the resident. The 
assessment should be conducted within the context of, and in compliance with, the state 
and federal guidelines related to the use of restraints and bed system entrapment guidance, 
including the Clinical Guidance for the Assessment and Implementation of Side Rails published 
by the Hospital Bed Safety Workgroup of the U.S. Food and Drug Administration. Further 
information can be obtained at the following web address: http://www.fda.gov/MedicalDevices/
ProductsandMedicalProcedures/GeneralHospitalDevicesandSupplies/HospitalBeds/default.htm

NOTE: The Direct Supply Panacea assist devices are intended for use as an aid in entering or exiting 
the bed sleep area, as well as a stable handhold during self positioning within the sleep area.

NOTE: The Direct Supply Panacea siderails are intended to provide a physical indication of the 
bed edge, as well as a stable handhold during self positioning within the sleep area.

Direct Supply Panacea assist devices or siderails are designed to be used with specific Direct 
Supply Panacea bed frames. Once mounted on the appropriate bed frame, assist devices or 
siderails become an integral part of the Direct Supply Panacea bed system. As such, these 
mounted assist devices or siderails can handle the same safe working load, within normal use 
conditions, of the appropriate bed to which they are mounted. 

Содержание Panacea 1000

Страница 1: ... it for future reference This guide will provide you with instructions warnings warranty information and other important information about your Direct Supply Panacea Siderails and Assist Device Share this information with your housekeeping nursing and maintenance staff to help ensure the bed is cared for properly 1 800 634 7328 directsupply com Siderails and Assist Device for Direct Supply Panacea...

Страница 2: ...Entrapment zones involve the relationship of bed components often directly assembled by the healthcare facility rather than the manufacturer Therefore compliance is the responsibility of the facility Please keep and refer to this Owner s Manual Introduction Definitions and Symbols NOTE Indicates a tip CAUTION Indicates correct operating or maintenance procedures in order to prevent damage to or de...

Страница 3: ...167 Bolts 2 3 11012033 SpaceTubes 2 4 12673105 Lock Nuts 5 16 18 Hex 2 5 12843788 3 8 Flat Washers 2 6 12843789 5 16 Flat Washers 2 SuggestedTools 7 16 Deep Well Socket with ratchet 1 2 Socket Wrench 3 8 Torque Wrench 1 Remove the plugs from positions A and B on the mattress deck A B Remove plugs as shown and attach the siderails or assist device in holes A and B on the head end of the bed ...

Страница 4: ... 5 16 washers Item 6 through holes in assist handle Item 1 Figure 3 4 Put bolts through the bushings Item 3 Place 3 8 washer Item 5 over the bolt Item 2 and thread nut Item 4 on the bolt Item 2 and torque to 17 lbs ft Refer to Figures 3 and 4 Figure 2 Figure 4 Figure 3 2 1 6 3 5 4 1 2 6 3 5 4 6 3 5 4 1 2 6 3 5 4 4 5 3 2 6 1 HEAD END ...

Страница 5: ... plugs from positions A and B on the mattress deck 2 Insert the siderail in holes A and B 3 Attach mounting clips from the bed to the siderail A B Remove plugs as shown and attach the siderails or assist device in holes A and B on the head end of the bed When mounted to the bed the latch must always face the center of the bed ...

Страница 6: ...check for loose hardware on a monthly basis Tighten loose hardware as stated in the installation instructions NOTE Assist devices are made for right or left side of bed as viewed from the foot of the bed The latch on both assist devices must face toward the center of the bed so they operate properly ...

Страница 7: ...hese openings Failure to do so could result in serious injury or death WARNING Risk of Serious Injury or Death Do not use the Direct Supply Panacea assist device as an assist until you have verified that it is up AND locked Injury to resident or caregiver may result if this procedure is not followed WARNING An optimal bed system assessment should be conducted on each resident by a qualified clinic...

Страница 8: ...d in their accompanying Direct Supply Panacea User Service Manual Read this manual and the accompanying bed manual in full prior to using this product The instructions for use of these devices also list the bed type or model with which they may be used WARNING Some states may prohibit siderails or consider siderails to be patient restraints Always assess whether restraints are necessary on a case ...

Страница 9: ...to someone else or at the end of the applicable limited warranty period identified below whichever is earlier Warranty Period Parts Only Anticipated Usable Device Life Siderails and Assist Device 3 years 3 years Anticipated Usable Device Life is based on normal use with proper maintenance cleaning and storage You should still inspect monitor and care for the device as described in this guide as th...

Страница 10: ...nc used under license Customer Service Our promise to you is that you will have a convenient and easy ordering experience receive quality Direct Supply Panacea Siderails and Assist Device for Direct Supply Panacea 1000 Adjustable Height Low Beds and enjoy outrageous customer service If you have any questions about the equipment you have purchased or would like to request warranty service please co...

Отзывы: