Part 1 - Remote Setup
7
1
Alarm Out LED
2
Alarm In
LED
3
Power LED
4
Network LED
5
Factory Reset Switch
1
Alarm Out LED
Displays alarm out status
2
Alarm In LED
Displays alarm in status
3
Power LED
Displays system operating status
4
Network LED
Displays network connection status
LED Status Indications
LED
Status
Description
Alarm LED
On
Alarm In/Out operating
Power LED
Off
No power connection
Blinking
System booting or upgrading
On
System operating
Network LED
Blinking
Normal network connection
5
Factory Reset Switch
Use to return all settings to the original factory settings. Connect the power and poke a straightened paperclip into
the factory reset switch hole. Hold the reset switch until the alarm in/out LED blinks several times. Release the reset
switch, and all of the encoder’s settings are now at the original settings it had when it left the factory.
•
Factory Reset during system booting
: All of the encoder’s settings are now at the original settings it had when
it left the factory.
•
Factory Reset during system operating
: The other settings except for protocol and system log are now at the
original settings it had when it left the factory.
•
Factory Reset via the IDIS Discovery program
: The other settings except for protocol, system log and network
settings are now at the original settings it had when it left the factory.
•
Factory Reset via the IDIS Discovery program(including network settings)
: The other settings except for
protocol and system log are now at the original settings it had when it left the factory.