Operating Humidity range
………………………….….……….……….10 to 90%RH (No Condensation)
Storage Humidity rang
e………………………….….……….……………5 to 95%RH (No Condensation)
Case Dimension (L x W x H)
………………………………….…………………………….94x74x28 (mm)
Weight
…….…………………………….………………………………………….………………..…… 120g
Notes:
Pls use the machine as the instruction listed to keep the long use lifetime of the machine.
1. The machine should be placed at the spot far from the Damp, High-Temperature, Dusty, Erosive,
and oxidative environment.
2. All parts will be free from the strong shake, hit, fall.
3. Touching the power adaptor with the wet hands is prohibited.
4. Pls hold the power adaptor head and do not pull the power cord when cut off from the socket.
5. Pls turn the power off when the machines not used for long time.
6. Pls do not open the cover and do not touch the inside parts.
7. Pls use the original factory power adaptor.
FAQ:
Before power on, pls check the connection line carefully. And make sure that all interfaces are
normally connected. The common trouble shooting way shows below:
No.
Problem Description
Solutions
1
Non-Power-Connected
1. Check if the power adaptor head is truly and correctly inserted the
power socket.
2. Check the power if it is in on status.
2
Receiver search no
signal
1. Confirm the coaxial cables are intact and reliable connection.
2.
Confirm the length of coaxial cable is too short. When the
transmission distance is short (less than 100 meters), you should
choose high channel or adding attenuator in coaxial cable for the
signal attenuation.
3. Confirm the TX and RX channel settings should be the same
4. Check the cable quality. ( Recommend use SYV-75/RG59 coaxial
standard cable)
3
Receiver no Picture
1. Confirm the HDMI cable of TX is intact and reliable connection.
2. Check the signal source is power on and output normal.
3. Check the signal source output resolution, may be set too high.
4.
Confirm the signal source whether contains HDCP key, use
special receiver is recommended.
5. Check the HDMI cable quality.