AS Autosampler Operator’s Manual
250
Doc. 065051-03 1/08
SAMPLE
SYRINGE
VOLUME
The volume of the sample syringe
installed. Press
Select
Δ
or
Select
∇
to
scroll through the choices.
If the AS is equipped with the
simultaneous injection option (see
), select either the 5,000 or
10,000
μ
L size.
For sequential and concentrate modes, any
sample syringe size (except 2.5 mL) can
be installed.
100, 250,
500, 1,000, 5,000,
10,000
μ
L
(default=250)
For simultaneous
injection mode: 5,000
or 10,000
μ
L
(default=5,000)
SAMPLE
SYRINGE
CONFIG
The action to be performed by the sample
syringe. These actions are used to
configure the syringe at initial setup or
after a new syringe is installed.
INITIALIZE
moves the syringe to an initial
position.
READY
is displayed when syringe
configuration is complete; no action
occurs. See
INITIALIZE
READY
PREP
SYRINGE
VOLUME
The volume of the prep syringe installed.
Press
Select
Δ
or
Select
∇
to scroll
through the choices.
250, 500, 1,000,
5,000, 10,000
μ
L
(default=5,000)
PREP
SYRINGE
CONFIG
The action to be performed by the prep
syringe. See the
SAMPLE SYRINGE
CONFIG
section for details.
INITIALIZE
READY
Screen Field
Description
Values
Содержание As
Страница 1: ...AS Autosampler Operator s Manual Document No 065051 Revision 03 January 2008...
Страница 190: ...AS Autosampler Operator s Manual 178 Doc 065051 03 1 08...
Страница 238: ...AS Autosampler Operator s Manual 226 Doc 065051 03 1 08...
Страница 338: ...AS Autosampler Operator s Manual 326 Doc 065051 03 1 08...
Страница 355: ...Index Doc 065051 03 1 08 Index 17 Z Z address 255...
Страница 356: ...AS Autosampler Operator s Manual Index 18 Doc 065051 03 1 08...