![diodor DIO-FL200W-WM Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/diodor/dio-fl200w-wm/dio-fl200w-wm_installation-and-operating-instructions-manual_2506075003.webp)
• The unit requires connection to a 230 AC 50Hz mains electricity supply.
• It is recommended that the unit is connected to the lighting circuit via a 5 amp fused spur and using Twin & Earth 2-Core
round flexible cable of at least 1mm
2
gauge (waterproof cable should be used for outdoor installations).
• It is also advisable to install a single pole wall switch to allow easy control of the floodlight [Fig. 1].
WARNING: Isolate the power supply before installation.
The
Diodor LED Powerhouse
can be fixed in position by EITHER:
Option 1: Attaching the U bracket to the mounting surface and attaching the
Powerhouse
to the U bracket, or Option
2: Clamping the pipe bracket to the U bracket around a pipe or pole, and then attaching the
Powerhouse
.
If attaching the
Powerhouse
direct to a wall using the U bracket:
• Select a mounting point which is strong enough to support the weight of the
Powerhouse
.
• Attach the
Powerhouse
to the U bracket using the two securing bolts provided [Fig.2].
• Position the unit against the mounting surface and mark the position for the U bracket, ensuring the wires can easily
reach the unit.
• Use the U bracket Fixing Holes [Fig.3] to mark the 4 drill holes required to secure the U bracket to the wall (and mark the
cable outlet location if required).
• Detach the
Powerhouse
from the U bracket, drill the wall and screw U bracket onto the wall using appropriate fixings
which are able support the weight of the
Powerhouse
.
• Once the U bracket is securely attached to the wall, offer the
Powerhouse
up to the U bracket and secure using the
securing bolts, spring washers and washers provided [Fig.2].
• Loosen the 4 screws holding the front of the connection box in place and remove.
• Feed the wire through the cable gland on the connection box gently tightening gland nut up against the gland body
[Fig. 4] to ensure the wire(s) is secured in place and no water can get though into the connection box.
• Wire the
Powerhouse
as described in Section 4.
2. WIRING REQUIREMENTS
3. FIXING THE Diodor LED Powerhouse
3.1. OPTION 1: ATTACHING THE Diodor LED Powerhouse VIA THE U BRACKET