background image

3 OF 8

IG022719-1.0

HYDROLUME

®

 SLIM 24V LED STRIP LIGHT

 

 INSTALLATION GUIDE

HYDROLUME

® 

SLIM 24V LED Strip Light

INSTALLATION GUIDE

INSTALLATION

1

TURN POWER OFF AT CIRCUIT BREAKER

2

SHOCK HAZARD!

 

May result in serious injury or death.

Turn power OFF at circuit breaker prior to installation.

DETERMINE LOCATION TO INSTALL 

COMPONENTS

AC IN

DC OUT

L

G

N

V

V+

+

1) Class 2 Driver

2) Control

3) Hydrolume

Refer to 

SYSTEM DIAGRAMS

WIRE GAUGE & VOLTAGE DROP

Ensure applicable wire is installed between driver, fixture, and any 

controls  in  between.  When  choosing  wire,  factor  in  voltage  drop, 

amperage rating, and type (in-wall rated, wet location rated, etc.)

3

ADHERE MOUNTING CHANNEL TO SURFACE

Once  adhesive  is  dry,  firmly  press  HYDROLUME  into 

mounting channel working one end to the other.

Mount channel to dry surface using a chlorine resistant 

waterproof adhesive. Allow adhesive to cure/dry.

 

 

NEC 680

When  installing  in  water,  install  in  accordance  with  NEC  680.  Per 

UL instructions It is required to mount strip light  with HYDROLUME 
Mounting Channel (DI-HL-MTCH) for these applications. 

UL LISTED 676 MODELS 

FOR UNDERWATER APPLICATIONS

For other applications that are not underwater, see

 INSTALLATION - UL 

LISTED 2108 MODELS.

ATTENTION: 

FIBERGLASS & VINYL LINED POOLS

Unlike  concrete  pools,  most  fiberglass  and  vinyl  lined 

pools have strict warranty guidelines that do not allow the 

user to deface the pool wall surface. Diode LED does not 

recommend  mounting  to  fiberglass  or  vinyl  pool  walls  and/

or defacing the surface in any way (ex. drilling into surface to 

route lead wires).  It is recommended to mount to a separate 

pool coping or lip to ensure your pool warranty is not voided. 

Always consult with your pool supplier and contractor for 

proper installation of 3rd party products.

Wall Mount

Coping Mount

Concrete Pools Only

Concrete Pools

Fiberglass Pools

Vinyl-Line Pools

Содержание HYDROLUME SLIM 24V

Страница 1: ...electrician 3 Do not modify or disassemble this product beyond instructions or the warranty will be void 4 Only install with a Listed Class 2 DC LED driver 5 Do not exceed maximum run recommended for...

Страница 2: ...TOOLS 1 2 3 4 1 Appropriate Junction Box 2 Class 2 rated Driver 3 Compatible Dimmer or Switch 4 HYDROLUME SLIM LED Strip Light 5 HYDROLUME SLIM Mounting Brackets or Channels DO NOT BEND LED STRIP LIG...

Страница 3: ...el to dry surface using a chlorine resistant waterproof adhesive Allow adhesive to cure dry NEC 680 When installing in water install in accordance with NEC 680 Per UL instructions It is required to mo...

Страница 4: ...ded driver will trip the internal auto reset of driver repeatedly turning the system on off To Class 2 LED Driver GFCI Circuit Breaker To Additonal HYDROLUME Pool Spa Junction Box Corrosion Resistant...

Страница 5: ...ation rated etc 3 MOUNT HYDROLUME TO SURFACE See mounting options a b c Mark placement for HYDROLUME Mounting Brackets roughly 12 inches apart Fasten brackets with M2 9 4 screw or similar size not pro...

Страница 6: ...r dimming control is installed Check for loose connections Lights are turning on off repeatedly Ensure driver is not overloaded An overloaded driver will trip the internal auto reset of driver repeate...

Страница 7: ...Output V Red Install appropriate wire gauge type V V LED Tape Light Fixture 8 REIGN 12 24V Dimmer4 V V L N AC Power 50 60Hz INPUT OUTPUT 1 Driver may not require a fault ground connection Refer to dri...

Страница 8: ...1 7 A 50 W 2 1 A 60 W 2 5 A 70 W 2 9 A 80 W 3 3 A 100 W 4 2 A 18 AWG 134 ft 68 ft 45 ft 33 ft 27 ft 22 ft 19 ft 17 ft 14 ft 16 AWG 215 ft 109 ft 72 ft 54 ft 43 ft 36 ft 31 ft 27 ft 22 ft 14 AWG 345 ft...