3 OF 8
IG022719-1.0
HYDROLUME
®
SLIM 24V LED STRIP LIGHT
INSTALLATION GUIDE
HYDROLUME
®
SLIM 24V LED Strip Light
INSTALLATION GUIDE
INSTALLATION
1
TURN POWER OFF AT CIRCUIT BREAKER
2
SHOCK HAZARD!
May result in serious injury or death.
Turn power OFF at circuit breaker prior to installation.
DETERMINE LOCATION TO INSTALL
COMPONENTS
AC IN
DC OUT
L
G
N
V
−
V+
+
−
1) Class 2 Driver
2) Control
3) Hydrolume
Refer to
SYSTEM DIAGRAMS
WIRE GAUGE & VOLTAGE DROP
Ensure applicable wire is installed between driver, fixture, and any
controls in between. When choosing wire, factor in voltage drop,
amperage rating, and type (in-wall rated, wet location rated, etc.)
3
ADHERE MOUNTING CHANNEL TO SURFACE
Once adhesive is dry, firmly press HYDROLUME into
mounting channel working one end to the other.
Mount channel to dry surface using a chlorine resistant
waterproof adhesive. Allow adhesive to cure/dry.
NEC 680
When installing in water, install in accordance with NEC 680. Per
UL instructions It is required to mount strip light with HYDROLUME
Mounting Channel (DI-HL-MTCH) for these applications.
UL LISTED 676 MODELS
FOR UNDERWATER APPLICATIONS
For other applications that are not underwater, see
INSTALLATION - UL
LISTED 2108 MODELS.
ATTENTION:
FIBERGLASS & VINYL LINED POOLS
Unlike concrete pools, most fiberglass and vinyl lined
pools have strict warranty guidelines that do not allow the
user to deface the pool wall surface. Diode LED does not
recommend mounting to fiberglass or vinyl pool walls and/
or defacing the surface in any way (ex. drilling into surface to
route lead wires). It is recommended to mount to a separate
pool coping or lip to ensure your pool warranty is not voided.
Always consult with your pool supplier and contractor for
proper installation of 3rd party products.
Wall Mount
Coping Mount
Concrete Pools Only
Concrete Pools
Fiberglass Pools
Vinyl-Line Pools