background image

1 OF 8

IG022719-1.0

HYDROLUME

®

 SLIM 24V LED STRIP LIGHT

 

 INSTALLATION GUIDE

®

HYDROLUME

® 

SLIM 24V LED Strip Light

INSTALLATION GUIDE

Input

24VDC Constant Voltage

Power

Standard

1.22W/ft. (1.5W/cut 

point)

Plus

2.44W/ft. (1.0W/cut 

point)

Max Run

Standard

65 ft.

Plus

32 ft.

Ambient 

Temp †

-4° - 122°F (-20° - 50°C)

1. Install in accordance with national and local electrical 

code regulations. 

2. This product is intended to be installed and serviced by a 

qualified, licensed electrician.

3. Do not modify or disassemble this product beyond 

instructions or the warranty will be void.

4. Only install with a Listed Class 2 DC LED driver. 
5. Do not exceed maximum run recommended for Strip 

Light.

6. Diode LED Strip Light is designed to be cut at designated 

cut points only. Cutting anywhere other than the cut 
points will result in damage to the Strip Light.

7. 

Failure  to  follow  safety  warnings,  and  installation 

instructions will void the warranty for this product.

SAFETY & WARNINGS

QUICK SPECS / MODELS

† Do not install product in environment outside listed 

temperature.

SUBMERSIBLE

DIMMABLE

24VDC

UV RESISTANT

IP68

POWER SUPPLY

CLASS

2

Содержание HYDROLUME SLIM 24V

Страница 1: ...electrician 3 Do not modify or disassemble this product beyond instructions or the warranty will be void 4 Only install with a Listed Class 2 DC LED driver 5 Do not exceed maximum run recommended for...

Страница 2: ...TOOLS 1 2 3 4 1 Appropriate Junction Box 2 Class 2 rated Driver 3 Compatible Dimmer or Switch 4 HYDROLUME SLIM LED Strip Light 5 HYDROLUME SLIM Mounting Brackets or Channels DO NOT BEND LED STRIP LIG...

Страница 3: ...el to dry surface using a chlorine resistant waterproof adhesive Allow adhesive to cure dry NEC 680 When installing in water install in accordance with NEC 680 Per UL instructions It is required to mo...

Страница 4: ...ded driver will trip the internal auto reset of driver repeatedly turning the system on off To Class 2 LED Driver GFCI Circuit Breaker To Additonal HYDROLUME Pool Spa Junction Box Corrosion Resistant...

Страница 5: ...ation rated etc 3 MOUNT HYDROLUME TO SURFACE See mounting options a b c Mark placement for HYDROLUME Mounting Brackets roughly 12 inches apart Fasten brackets with M2 9 4 screw or similar size not pro...

Страница 6: ...r dimming control is installed Check for loose connections Lights are turning on off repeatedly Ensure driver is not overloaded An overloaded driver will trip the internal auto reset of driver repeate...

Страница 7: ...Output V Red Install appropriate wire gauge type V V LED Tape Light Fixture 8 REIGN 12 24V Dimmer4 V V L N AC Power 50 60Hz INPUT OUTPUT 1 Driver may not require a fault ground connection Refer to dri...

Страница 8: ...1 7 A 50 W 2 1 A 60 W 2 5 A 70 W 2 9 A 80 W 3 3 A 100 W 4 2 A 18 AWG 134 ft 68 ft 45 ft 33 ft 27 ft 22 ft 19 ft 17 ft 14 ft 16 AWG 215 ft 109 ft 72 ft 54 ft 43 ft 36 ft 31 ft 27 ft 22 ft 14 AWG 345 ft...

Отзывы: