23
3) To change the mode, repeat steps 1 and 2.
4) To exit the
SEtUP
menu, push the SAVE “MEM” (T2) key twice.
T2
PASSWORD
The
SEtUP
Menu can be protected by entering a personalised
user password.
1) Rotate the ENCODER - A (E1) knob, until both the displays
(D1-D2) read
PAS 0
, which indicates that no password has
been entered.
D1
D2
E1
2) Rotate the ENCODER - V (E2) knob until the DISPLAY PA-
RAMETERS V (D2) display shows the number required (from
0 to 999) (this operation does not need to be confirmed).
D2
E2
3) Once a PASSWORD has been entered, each time the
SEt-
UP
Menu is accessed, to be able to use it the correct number
must be set and confirmed by pushing the PRG key.
4) To change the PASSWORD, repeat steps 2 and 3.
5) To exit the SEtUP menu, push the SAVE “MEM” (T2) key twice.
T2
IMPORTANT: If the password is lost, contact DINSE it’s tech-
nical service department.
BLOCKS
If enabled, this function allows the operator to block or limit use of
the welding machine and/or certain welding parameters / functions.
There are 4 possible options to choose from:
•
BLOCK
no
- Does not allow any block to be activated for the
welding machine, but allows the operator to unblock the machine
if it was blocked in the past.
•
BLOCK
L1
- The operator can only weld using the parameters
set prior to the block, and can set and/or modify the welding pa-
rameters, using the knobs on the control panel on the welding
machine and the wire feeder (if installed).
•
BLOCK
L2
- The operator can only weld using the parameters
set prior to the block and cannot set and/or modify the welding
parameters.
•
BLOCK
L3
- Allows the voltage, current, and electronic induct-
ance value to be corrected by ±15%.
1) Rotate the ENCODER - A (E1) knob until the DISPLAY PA-
RAMETERS - A (D1) display reads
bLC
and the DISPLAY PA-
RAMETERS - V (D2) display shows the four choice options of:
no
(NO BLOCK),
L1
(PARTIAL BLOCK),
L2
(TOTAL BLOCK),
L3
(PERSONALISED BLOCK).
2) Rotate the ENCODER - V (E2) knob and choose one of the 4
options (this operation does not need to be confirmed).
D1
D2
E2
E1
3) To change the mode, repeat steps 1 and 2.
4) To exit the
SEtUP
menu, push the SAVE “MEM” (T2) key twice.
T2
SERIAL NUMBER
This function provides the serial number of the control board of
the welding power source, which could be helpfull for technical
assistance.
1) Rotate the ENCODER - A (E1) knob until the DISPLAY PA-
RAMETERS - A (D1) display shows the
SEr
function, and the
DISPLAY PARAMETERS - V (D2) display reads
nUM
.
D1
D2
E2
T5
E1
2) When the PRG key is pushed, a 16-character text will pass
by, indicating the board’s serial number.
Содержание DIX PI GO 2006.M