• The connection between charger cable and battery terminal shall be
reliable, to prevent the generator from moving or loosening.
• Follow steps in the User's Manual for proper operation.
• In the process of charging, if current exceeds the value of rated
current, DC protector will switch off the output. Press DC protector to
"ON" to restart charging. If the DC protector switches off again, stop charging
immediately and contact your dealer.
Tip:
Measure specific gravity of electrolyte to determine whether the battery
is charged full. In the case of full charging, the specific gravity of electrolyte
is between 1.26 and 1.28. It is recommended to check specific gravity of
electrolyte at least once an hour, to prevent the battery from being
overcharged.
!
WARNING
Never smoke, and never connect or disconnect the connection to the battery
during charging. The spark generated will ignite gas around the battery.
Battery electrolyte contains sulfuric acid, which is toxic and with the risk of
burning. Please avoid expose to skin, eyes and clothing.
In the case of exposing to sulfuric acid accidentally, treatment method is:
• External exposing: flush with large amount of water
• Ingestion by mistake: Drink large amount of water or milk, and drink
milk, egg liquid or vegetable oil containing magnesium oxide. Send
the victim to hospital immediately
• Eye exposing by mistake into eyes: Flush with water for 15 minutes,
and seek medical treatment timely.
Tip: The battery can generate explosive gas, so please keep it far away
from spark, flame or cigarette, etc. Please keep ventilation when
charging or using the battery in a con fined space. Close your eyes as
far as possible when working near the battery.