Ver.: 1810-11
7
EN
5.5
Connection Sequence
Start the charging process
Stop the charging process
1. Connect the power grid connector to the grid.
1. Unlock the vehicle connector on the vehicle and
unplug it.
2. Connect the vehicle connector to the vehicle.
2. Disconnect the grid connector.
The NRGkick can, however, also remain connected
to the power grid socket permanently.
5.6
Theft-Protected and Tamper-Proof
Electric vehicles with type 2 charging socket lock the vehicle connector after it is plugged in. This means
your NRGkick is protected against theft during and after charging. The socket can only be unlocked via the
vehicle.
NRGkick has a protection system to prevent the charging current settings being tampered with by
passersby:
•
The charging current can only be adjusted using the selection button after connection to the power
supply. If the vehicle connector is already plugged in, you have max. 10 seconds left to adjust the
settings (see 5.2).
•
The charging current can only be re-set by interrupting the charging process within 2 minutes of
starting the charging process (see 5.3).
•
After this, it will no longer be possible to modify the charging current
–
even if the power supply is
disconnected and reconnected, which causes the NRGkick to re-initialize.
It will then only be possible to change the charging current again after the type 2 charging socket
is unlocked via the vehicle.
Additionally, it is only possible to reset the Access Code for connecting to a smartphone (see 7.2) if the
vehicle connector is unlocked and unplugged.
5.7
Error Mode
Errors are shown with the following sequences of flashing LEDs on the NRGkick:
•
5x flashing of all LEDs + short break (repeating)
Indicates a potential error of the residual current protection mechanism or that it has been triggered, the
NRGkick is in “Error”
-Mode.
Note:
With the
“
Energy meter and Bluetooth
”
product option, you can read
out the error with the NRGkick App on a smartphone.
The
“
Error
”
mode can only be reset by disconnecting the power supply. In case of an error, check for a
vehicle-related fault or a fault in the plug connections.
•
Flashing of the Status LED and the LED of the selected charging current (repeating)
Indicates an irregularity of the PE conductor test. Make sure that the electrical installation and the
protective conductor are connected correctly.
This error can be acknowledged by pressing the selection button for at least two seconds.
Note: In some countries, e. g. Norway, ground-free power grids are prevalent. Charging in these grids is
possible via acknowledgement of the error as described before. After acknowledgement this is shown
permanently during the charging process with the flashing green Status LED.
Содержание NRGkick 16A
Страница 2: ......
Страница 3: ...Ver 1810 11 1 EN Instruction Manual...
Страница 15: ...Ver 1810 11 1 ES Manual de instrucciones...
Страница 27: ...Ver 1810 11 1 PT Manual de Instru es...
Страница 39: ...Ver 1810 11 1 TR Kullan m k lavuzu...
Страница 51: ...Ver 1810 11 1 FI K ytt ohje...
Страница 63: ...Ver 1810 11 1 SE Bruksanvisning...
Страница 75: ......
Страница 76: ......