OPERATOR
’S MANUAL
with Maintenance Information
Safety Rules
2
The relevant conditions of using
the equipment
The surface of work ground should be flat and
hard with no obstacles in air and the safety
distance between the equipment and
high-tension line is adequate.
The environment temperature should be within
-20
℃
~40
℃
;
Height above sea level ≤1000m.
The environment humidity
≤ 90%.
Electrical power: AC 110~230V±10%,
50~60Hz.
Work cycle
The life of designed work cycle is no more than
40000 times.
Intended Use
This machine is intended to be used only to lift
personnel, along with their tools and materials
to an aerial work site.
Safety Sign Maintenance
Replace any missing or damaged safety signs.
Keep operator safety in mind at all times. Use
mild soap and water to clean safety signs. Do
not use solvent-based cleaners because they
may damage the safety sign material.
Operator
Only the trained and qualified are permitted to
operate this machine. Always use safety belt
and helmet when aerially working.
If you are subject to dizziness or seizures, or
are bothered by heights, you must not operate
this type of machinery.
An operator must not use drugs or alcohol that
can change his/her alertness or coordination.
An operator on prescription or
over-the-counter drugs needs medical advice
on whether or not he/she can safely operate
machines.
Electrocution Hazard
This machine is not electrically insulated and
will not provide protection from contact with or
proximity to electrical current.
Maintain safe distances from electrical power
lines and apparatus in accordance with
applicable governmental regulations and the
following chart.
Voltage
Phase to Phase
Minimum Safe
Approach Distance
Meters
0 to 300V
Avoid Contact
300V to 50kV
3.05
50kV to 200kV
4.60
200kV to 350kV
6.10
350kV to 500kV
7.62
500kV to 750kV
10.67
750kV to 1000kV
13.72
Allow for platform movement, electrical line
sway or sag and beware of strong or gusty
winds.
Keep away from the machine if it contacts
energized power lines. Personnel on the
ground or in the platform must not touch or
operate the machine until energized power
lines are shut off.