21
Picture fifteen
Picture sixteen
c Adjust the position of PCB board so that the ready to be heated parts is
under the upper warm wind nozzle (Like picture sixteen)
d Adjust the adjusting knob of head blow-dryer up and down so that the upper warm
wind nozzle is 2-3mm higher than the surface of PCB board
e Choose the touch screen interface (like picture five), click “start”, then the upper
heater begin to heat
f Now the screen will show red. light blue.green three curves (Picture seventeen)
The temperature curve of external couple (light blue)
The current temperature curve of internal couple of upper heater (red)
The current temperature curve of internal couple of bottom heater (green)
Picture seventeen
(D) Use the external couple to adjust the temperature
Statement: Statement: In this step, fault operating will cause
temperature deviation or even out of control, please be careful!