DHM-15B HEIGHT AND WEIGHT MACHINE
5
Display 500 in the height screen means the present corrected value is 500 (range:
1-999).Display
0.00 in weight screen means the present weight. Put something
with confirmed weight on the saddle. After a stable weight display, press + or – to
adjust the display data.
You can press SEL when it is required to measure again.
Press ENT store and exit. Press ESC exit without store.
After the adjustment, please see the corrected value, if it reaches the maximum figure,
there may be something wrong with the scale.
Height adjustment
:
Choose menu code
1-04
,
press ENT into adjustment state.
Display 00.0 in the height screen means the present height. Display 120 in the weight
screen means the present corrected value is 120(scale: -400-400). Put something with
confirmed height on the saddle. After a stable height display, press + or – to adjust the
display data.
You can press SEL when it is required to measure again.
Press ENT store and exit. Press ESC exit without store.
The division is 0.1cm.After the adjustment, please see the corrected value, if it
reaches the maximum figure, there may be something wrong with the scale.
Pronunciation interval setting
:
Choose menu code
1-05
,
press ENT into adjustment state.
Display
4 in weight screen means the present parameter is 4 with a scope of
0-50. The display value 4 means the interval of pronouncing “welcome” is 20 seconds.
The present value multiply 5 refer to the interval seconds of pronunciation
“welcome”.
Press
+ or - adjust the present value into that of needed.
Press ENT
,
store the results and exit. Press ESC exit without being stored.
Pronunciation setting
: