3.1.3.2. Pressure settings
While in maintenance mode of the OnRoad device, pressure settings can be accessed withing the main
menu using the
button. Inside this menu you can set lower and upper pressure limits.
While displaying current pressure, press
to edit
Lower pressure limit, press
to edit
Upper pressure limit, press
to edit
Exit menu, press
to exit
Table 3.5.
Pressure settings menu
3.1.3.2.1. Lower pressure limit
If the back pressure is lower than the value of lower pressure limit for period longer than 10 sec, alarm will
be activated. If the back pressure returns to the normal value for period longer than 10 sec, alarm will be
deactivated.
To signal the low-pressure alarm,
ERROR 35
code is shown on the screen.
3.1.3.2.2. Upper pressure limit
If the back pressure is higher than the value of upper pressure limit for period longer than 10 sec, alarm will
be activated. If the back pressure returns to the normal value for period longer than 10 sec, alarm will be
deactivated.
To signal the high-pressure alarm,
ERROR 36
is shown on the screen.
Note: The alarm light might turn on even while the system and filter are in normal operating condition,
usually when the driver accelerates the vehicle. This is normal behaviour, and driver’s attention isn’t
required.
76 mbar
L(L): 15mbar
E: L(L)= 15mbar
L(U): 250mbar
E: L(U)= 250mbar
[ < - ]
L(L): 15mbar
L(U): 250mbar