background image

 XMC(N)

 MODELS:

 

XMC712N 

1.7kW/12kWh  

Storage and 1kW Convector

 

XMC718N 

2.55kW/18kWh  

Storage and 1.5kW  Convector

 

XMC724N 

3.4kW/24kWh  

Storage and 2kW Convector

INSTALLATION

 

 

AND

 

 

OPERATING

INSTRUCTIONS

IMPORTANT

PLEASE READ THIS LEAFLET CAREFULLY AND  RETAIN FOR FURTHER USE.  

NOTE ALSO THE INFORMATION GIVEN ON THE HEATER

COMBINED STORAGE AND 
CONVECTOR HEATER

 

The installation must be carried out by a trained competent personnel.

 

A means for disconnection must be incorporated in the 

fi

 xed wiring by a double pole switch with a contact separation 

of a minimum of 3mm and in accordance with the current IEE Wiring Regulations

 

The heater must not be installed immediately below a 

fi

 xed socket outlet.

 

The heater is not suitable for connection to a 30A ring circuit (24 hour peak supply).

 

Do not position the heater under windows where curtains can contact the heater casing.

 

WARNING - THE SURFACES ON THIS HEATER CAN BE HOT

 

This heater meets EN60335 safety requirements. However, any heater type becomes  hot in normal operation. Care 
must be taken to ensure that prolonged skin contact with the heater does not occur.

     WHERE YOUNG CHILDREN, INFIRM PERSONS, OR THE AGED ARE PRESENT THIS APPLIANCE MUST BE 

ADEQUATELY GUARDED. Contact your installer or manufacturer for further advice.

  This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless they have been given supervision for instruction concerning 
use of the appliance by a person responsible for their safety.  Children should be supervised to ensure that they do 
not play with the appliance.

 

This appliance is very heavy and must be securely 

fi

 xed to a wall. DO NOT UNDER ANY CIRCUMSTANCES 

ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING EXPERT ADVICE.

  To maintain stability, it is essential that the heater is placed on a level surface.

 

This heater must be installed where it is impossible for switches and other controls to be touched by a person using 
a bath or shower.

 

IMPORTANT - Due to the newness of materials the heater will produce a slight smell for the 

fi

 rst few days of 

operation.  ROOMS MUST BE WELL VENTILATED AND YOUNG CHILDREN, CAGED BIRDS, OR PERSONS 
WITH RESPIRATORY COMPLAINTS MUST NOT  REMAIN IN CLOSE PROXIMITY TO THE HEATER DURING 
THE FIRST 48 HOURS OF THE COMMISSIONING PERIOD.

 

IF, DURING ANY REASSEMBLY OF THE HEATER, A PART OF THE THERMAL INSULATION SHOWS DAMAGE 
OR DETERIORATION WHICH MAY IMPAIR SAFETY, IT SHOULD BE REPLACED BY AN IDENTICAL PART.

Содержание XMS718N

Страница 1: ...RESENT THIS APPLIANCE MUST BE ADEQUATELY GUARDED Contact your installer or manufacturer for further advice This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision for instruction concerning use of the appliance by a person responsible for their safety Childr...

Страница 2: ...heater sitting firmly on the floor 3 Mark the position of the two outside corners of the wall bracket with the heater pushed tight against the wall Remove the wall bracket from the heater by removing the screw at each end Place the heater to one side and reposition the bracket against the wall using the corner marks for alignment Four fixing positions must be chosen for the 724N three for the 718N...

Страница 3: ... home then securely tighten the two screws in the block 11 12 Fit the front layer of bricks again with the recess towards the element The complete core will comprise 712N 2 x 4 Brick Columns 718N 3 x 4 Brick Columns 724N 4 x 4 Brick Columns 13 Replace the inner front complete with insulation by locating its bottom edge behind the front lip of the chassis and inserting retaining screws along the to...

Страница 4: ...r heater The storage heater takes in energy when electricity tariffs are low and dissipates it when tariffs are normal The convector heater provides an instant boost on demand from normal tariff electricity 1 Ventilate rooms well during commissioning 2 Do not move the heater in any way once installed without the services of a competent electrician 3 Do not cover the heater with clothing etc at any...

Отзывы: