English
TRP 100 M, TRP 100 W
EN-4
1810/B
www.dimplex.de/en
NOTE
NOTE
7. Control description
7.1 Control unit
The heating device is equipped with a configurable
electronic control, consisting of a display and six touch
screen keys. The control unit is located on the top on
the right. All settings can be selected using the six keys
on the user interface.
The set functions and values are shown on the display.
7.3 Display
The display lights up when this key is activated. If no
changes are made for a prolonged period, the display
switches off. If no key is pressed, the display returns to
the main menu after 30 seconds.
When the ENTER key is pressed, the 4-digit device
PIN is shown.
7.4 Battery change
The control includes a real-time clock with calendar
function. The clock has a button cell battery (type
CR2032, 3V), which supplies the clock with power in
the event of a power failure.
The battery compartment is located on the rear side of
the control unit.
7.2 Key functions
MAIN MENU
Setting date and time
Timer week program
Manual operation
Frost protection mode
BACK
Return to the previous program item
Keys
Used to navigate through the menu and to change the
setting values.
ENTER
Saving settings.
FORWARD
Special functions such as switching to the next
programme item in timer mode or activating the run-
back timer.
Unlock the battery compartment (A) and pull it out
(B).
The battery is located on the rear side (C).
Pull out the button cell and replace it (D). Observe
the correct polarity (+ pole as shown).
Carry out assembly in reverse order.
Weekday
Time
On/Off
Back
Menu
Advance
Setting keys
Enter key
Adaptive startup
Blocked
Audio
Connection
Timer
Manual
Frost protection
Time/date
Advance
A
B
C
D