background image

 

 

7

 

 

 

 

6.3.2 Cold air fan 

Pressing button D causes the integrated fan with-
out heating action to be switched on. The cold air 
mode is indicated by means of the green indicator 
light D1.  
The fan operating time can be set by pressing 
button C once or several times.  
The following time settings are available: 
30 minutes (1/2h), 60 minutes (1h) or 
120 minutes (2h), off. 

1h

2h

1/2h

2

1

3

4

6

9

2

7

10

A1

B1

A

C

D

B

D1

 

6.4 Comfort Mode (thermostat-controlled fan) 

In the comfort mode, also the fan heater – in addition to 
the radiant heater - is controlled by the thermostat. 

To activate the Comfort mode: 

Unit must be switched on (power-on indicator light 
A1 is illuminated) 
Press button A for three seconds until indicator 
light A1 is flashing. 

To exit from the Comfort mode: 

Press button A once more (indicator light A1 ex-
tinguishes, heater is off). 

After the heater is switched on again (press but-
ton A once more) the appliance resumes normal 
operation (as described under "6.1 On/Off But-
ton") 
 

7. Overheat Protection 

For your safety, the towel warmer/rapid heater is 
equipped with an overheat protection each for the func-
tions "Radiant On” and "Fan heater On”. 
If the heater becomes excessively hot, the appliance is 
automatically switched off. 

Resetting the overheat protection 

After the cause of tripping the overheat protection has 
been eliminated (e.g. air slots were covered), the appli-
ance can be restarted.  
The "radiant heat" overheat protection will automatically 
reset once the appliance has cooled down sufficiently. 
The overheat protection for the integrated fan heater 
must be reset  manually by switching the heater off (ac-
tuate button A) and allowing the appliance to cool down. 

Should the overheat protection trip repeatedly, please 
consult your customer service agent. 
 

8. Malfunctions 

In the event that defects in your appliance result in mal-
functions, please contact your customer service agent.  
Provide the service agent with a detailed description of 
the malfunction. 
For processing the service call, the product number (E-
number) and the manufacturing date code (FD-number) 
of the appliance are required. These data can be found 
on the rating plate (at the rear of the appliance). 

Repairs and interventions in the appliance may only be 
performed by a qualified electrician or the customer ser-
vice. 

 
9. Cleaning the Appliance 

Before the appliance can be cleaned it must be switched 
off  and have cooled down. 
Wipe the outside of the heater with a soft, damp cloth 
and then dry. Do not use scouring powder or furniture 
polish for cleaning as these may damage the housing. 
Dust that may have accumulated in the appliance can be 
removed from the outside with a vacuum cleaner. 
 

10. Technical Data 

Rated capacity

 

1500 W 

Radiant heating

 

700 W 

Fan capacity

 

800 W 

Voltage

 

230V~ 50 Hz 

Protection type

 

IP 24, splashproof 

Safety class

 

II, double insulated 

Dimensions without rail  
Dimensions with rail 

440 x 1010 x 121 mm (W x H x D)
470 x 1010 x 267 mm (W x H x D)

Weight 13 

kg 

 

11. Warranty

 

Authorised dealers can provide information on the terms 
and conditions of warranty. The warranty is not valid 
without a sales receipt marked with the date of purchase. 
 
 

Recycling 

The appliance must not be disposed in the 
normal household rubbish. Check with your 
local authority or retailer for recycling advice

Содержание TRFB 150

Страница 1: ...hen Kunststoffen eingehalten wer den siehe Abschnitt 2 Mindestabst nde Die Anschlussleitung darf nicht ber das hei e Ger t gelegt werden 2 Mindestabst nde Montage Das Heizger t darf nur in senkrechter...

Страница 2: ...separate Heizsysteme Strahlungsheizung mit W rmeabgabe ber die erw rmte Oberfl che W rmeabgabe durch einen L fter mit separatem Heizelement ber die Luftauslassschlitze an der Unterseite des Ger tes 1h...

Страница 3: ...ch ausreichender Abk hlung wieder ein Der berhitzungsschutz f r den integrierten Heizl fter muss durch Abschalten des Heizger tes Taste A bet ti gen und anschlie ender ausreichender Abk hlung ma nuell...

Страница 4: ...die entsprechenden VDE Vorschriften die Bestimmungen der rtlichen Versorgungsunternehmen oder unsere Montage und Gebrauchsanweisung nicht beachtet worden sind Durch etwa seitens des Endabneh mers ode...

Страница 5: ...c materials are maintained see Section 2 Minimum Clearances The supply cord must not be placed over the hot ap pliance 2 Minimum Clearances Mounting The heating appliance may only be mounted and oper...

Страница 6: ...arate heating modes Radiant heating via the heated surface Fan heater The heat is given off by a fan with a separate heating element via the air outlet slots on the bottom of the appliance 1h 2h 1 2h...

Страница 7: ...grated fan heater must be reset manually by switching the heater off ac tuate button A and allowing the appliance to cool down Should the overheat protection trip repeatedly please consult your custom...

Страница 8: ...Dimplex Deutschland GmbH Phone 49 0 9221 709 564 Subject to technical changes Am Goldenen Feld 18 Fax 49 0 9221 709 589 D 95326 Kulmbach E Mail kundendienst hauswaerme glendimplex de Internet www dimp...

Отзывы: