background image

 

 

 

                  Installation and Operating Instructions 

 
Air Curtain 
Model AC6   

 

 

 

 

 

 

    

08/17132/ 0 

 
 
 

IMPORTANT  

 

These instructions should be read and carefully retained by the user. 

 
The installation of this appliance should be carried out by a competent electrician and be in 
accordance with the current IEE wiring regulations.  Tools required are an electrical screwdriver with a 
3mm wide blade, a No 2 posidriver, a 7mm AF open ended or box spanner, an 8mm open ended 
spanner. 
 
 

Special instructions on Fitting the heater to a wall or ceiling:- 

 
Solid brick or concrete walls must be drilled and plugged with Rawlplug No 10 size FIBRE inserts.  
The plug must be located in the solid part of the wall, not just in the plaster layer. 
 
 
 
For panelled internal walls or ceilings, it is best to locate the studding, position the heater fixing 
bracket accordingly and use No 10 size wood screws.  If it is not possible to locate the studding, use 
type M5 Rawlplug INTERSETS, making the 1Omm holes with a drill rather than a bradawl or a 
screwdriver. 
 
 

DO NOT COVER OR OBSTRUCT 

the air inlet or outlet grille. 

 
 
 
 

Fixing Positions

 

 
 
 

Ceiling 
mounting 

 
 
 

 
 
 
 
Wall 
mounting 

 
 
 
 
 
 
Heaters may be mounted end to end for wide doorways 
 

 

Tel: 

+44

  

(0)191 490 1547 

Fax: 

+44

 

(0)191 477 5371

 

Email: 

[email protected]

  

Website: 

www.heattracing.co.uk 

                  www.thorneanderrick.co.uk

 

Содержание THORNE & DERRICK AC6

Страница 1: ... drilled and plugged with Rawlplug No 10 size FIBRE inserts The plug must be located in the solid part of the wall not just in the plaster layer For panelled internal walls or ceilings it is best to locate the studding position the heater fixing bracket accordingly and use No 10 size wood screws If it is not possible to locate the studding use type M5 Rawlplug INTERSETS making the 1Omm holes with ...

Страница 2: ...er to the required angle then firmly tighten the hexagonal headed screws using the 8mm spanner 5 Connection to the fixed wiring of the premises should be done through an adjacent 30 amp double pole switch 6 Connection from the remote control switch may be carried out Refer to circuit 1 and 2 opposite for removal and substitution of wires within the appliance 7 Cable connection should be carried ou...

Страница 3: ... blower and illuminates neon indicator 3 Select and switches marked E and D as required Switch Cooling E 3kW heating D 3kW heating E D 6kW heating Maintenance WARNING DISCONNECT SUPPLY before carrying out maintenance AC6 Heater Circuit Diagram 1 Wiring the Remote Control Switch Circuit Diagram 2 ...

Страница 4: ...h for stain removal a weak soap solution can be applied then wipe dry After Sales Service Your Dimplex Air Curtain is guaranteed for one year from date of purchase We undertake to exchange or repair free of charge within this period any part found to be defective due to a manufacturing fault This guarantee in no way prejudices your rights under common law Should you require after sales service ple...

Отзывы: