background image

  

 

Installation and Operating Instructions

  

 

TDTR 175 W, TDTR 350 W   Heated Towel Rails 

tdtr-gb_ba   04/11/A

 

 

1. Important Information  

These installation and operating instructions should be read 
carefully and retained for future reference. Ensure that these 
instructions are passed on to any new owner. 

  The towel rails are not intended for use other than indoors 

in closed rooms, to dry and warm damp towels and gar-
ments. 

  The appliance must not be subjected to any jets of water, 

e.g. when cleaning walls. 

  To ensure safe operation, install and connect the appli-

ance only in accordance with these operating instructions. 

  The appliance should be installed by a qualified electri-

cian in accordance with all relevant safety regulations. 

  Repairs to the appliance, or any other interventions, may 

only be performed by qualified persons or the after-sales 
customer service. 

  In the event of any defect (e.g. appliance or power cord is 

damaged, unit is not working), disconnect the appliance 
from the power supply. Shut off circuit breaker. 

  In the event of extended periods of non-use, the appliance 

must be disconnected from the power supply. 

  Caution! The outside of the appliance gets hot when in 

use. 

  Do not allow heater to be operated by children or other 

persons incapable of using the appliance in a safe man-
ner. Children must be prevented from playing near the 
appliance. 

  Do not use the appliance in rooms where flammable 

gases or liquids are stored or used. 

  It is of particular importance to ensure that all applicable 

safety regulations for bathrooms, shower rooms, swim-
ming pools, etc., are complied with.  

 

2. Minimum Clearances, Installation 

The heater may only be mounted and operated on a vertical 
wall in a vertical position, as shown in the illustration.  

During installation, ensure that the protection zones in accor-
dance with VDE 0100 Part 701 are complied with.  
The appliance may only be installed in protection zone 2 or 
outside the protection zone. 
The appliance should be installed such that it is out of reach 
of a person in the bath or shower. 

To prevent any risks for small children due to accidental con-
tact with the appliance, the lowest rail of the heater must be 
at least 600 mm above the floor. 

Do not install the appliance directly under wall socket outlets.  

The power socket outlet and/or the appliance plug must be 
accessible after the appliance has been installed. 

It is imperative that the minimum clearances as indicated in 
the installation drawing be maintained. 

All wall brackets supplied must be used. 

Before proceeding with the installation, please check that the 
screws and wall plugs are suitable for the particular type of 
wall. 

 

All dimensions in mm. 

 

 

Type 

Dimension A 

Dimension B 

Dimension C 

Dimension D 

TDTR 175 

250 

390 

453 

610 

TDTR 350 

380 

625 

602 

843 

 

Mounting procedure:

 

I  Mark mounting holes for wall brackets (Dimensions A and B) 

on the wall in a horizontal plane observing the clearances in-
dicated above. Minimum clearances must be maintained. 

II  Drill holes and insert wall plugs. 

 

 

III  Secure outer wall bracket sleeves (a) to the wall using 

screws. 

IV  Attach inner wall bracket sleeve (b) to towel rail with clamp-

ing pieces (c and d) and screw (e) as shown. 
Ensure that the clamping pieces are arranged correctly! 
Only tighten the screw slightly to enable subsequent hori-
zontal alignment.  

V  Align wall bracket sleeves on heater according to dimen-

sion illustration (Dimensions A and B). 

 

GB

 

Содержание TDTR 175 W

Страница 1: ...wimmbädern usw wird be sonders hingewiesen 2 Mindestabstände Montage Das Heizgerät darf nur in senkrechter Anordnung wie im Bild gezeigt an einer senkrechten Wand montiert und betrieben werden Bei der Montage sind die Schutzbereiche nach VDE 0100 Teil 701 zwingend zu beachten Die Montage des Gerätes darf nur im Schutzbereich 2 oder außerhalb des Schutzbereichs erfolgen Das Gerät ist so zu installi...

Страница 2: ...ehoben werden wenden Sie sich bitte an ihre Elektrofachwerkstatt oder die nächstgelegene Kundendienststelle Für die Auftragsbearbeitung werden die Erzeugnisnummer E Nr und das Fertigungsdatum FD des Gerätes benötigt Diese Angaben finden Sie auf dem Typschild Reparaturen und Eingriffe in das Gerät dürfen nur von einem Elektrofachmann oder dem Kundendienst ausgeführt werden 6 Kundendienst Ersatzteil...

Страница 3: ...m Clearances Installation The heater may only be mounted and operated on a vertical wall in a vertical position as shown in the illustration During installation ensure that the protection zones in accor dance with VDE 0100 Part 701 are complied with The appliance may only be installed in protection zone 2 or outside the protection zone The appliance should be installed such that it is out of reach...

Страница 4: ...t be remedied please contact your local electrical retailer or the nearest customer service The product number E number and the manufacturing date FD of the appliance are needed to process the order This information can be found on the rating plate Repairs to the appliance or any other intervention may only be performed by a qualified electrician or the after sales cus tomer service 6 Customer Ser...

Отзывы: