Dimplex SCH5 Скачать руководство пользователя страница 2

                                        

 

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE 

                                                                                               
                                                                                               
                                                                                               

                                                                                                                  
Electrical Connection 

 

This heater must be used on an ~230V AC supply only and the voltage 
marked on the heater must correspond to the supply voltage. 
 
To  comply  with  the  I.E.E.  Wiring  Regulations,  the  appliance  must  be 
earthed;  the  supply  circuit  must  be  adequate  for  the  input  of  the 
appliance, and the circuit protected by a suitable fuse. This appliance 
has a loading of 500 Watts. 
 
If the heater is to be connected to a fixed electricity supply, a suitable 
termination  must  be  provided  adjacent  to  the  final  position  of  the 
appliance.  In  this  instance,  such  a  termination  can  be  a  double  pole 
switch with a contact separation of at least 3mm in all poles. 
 
The  SCH5  if  converted  to  floor  standing  by  adding  feet  must  also  be 
fitted with a rewireable UK 3 pin plug incorporating a 13 amp fuse. The 
13 amp fuse must be approved by ASTA to BS1362. 
 
The  wires  in  the  mains  lead  are  coloured  in  accordance  with  the 
following code: 
 

Green and Yellow 

– Earth 

Blue                       - Neutral 
Brown                    - Live 

 

General 

 

The  Dimplex  SCH5  Convector  heater  is  primarily  designed  for  wall 
mounting. Feet are, however, available (Part no. CH9101) and enable 
the heater to be converted to floor standing units if required. 
The  heater  is  designed  either  for  individual  operation,  or  if  wall 
mounted, may be connected together in multiples with a connector kit 
(Part no.CH0471) 
As  supplied  the  Dimplex  SCH5  convector  heater  does  not  have  any 
controls.  Your  electrical  supplier will  be  able to  advise  on  timeswitch 
or  thermostatic  controls  which  would  be  suitable  where  multiple 
installations are involved.(see warning above).

 

Safety  

 

For  your  safety,  this  appliance  is  fitted  with  a  thermal  cut  out.  In  the 
event  that  the  product  overheats,  the  cut  out  switches  the  heater  off 
automatically. 
 
To  bring  the  heater  back  in  to  operation,  remove  the  cause  of 
overheating, then switch off the electrical supply to the heater for a few 
minutes. 
 
When the heater has cooled sufficiently, switch the heater on.

 

Dimensions 
 
 

Wall mounting (singly) 

(Please refer to Fig.1 and 2)

 

 
 

Installation and Operating Instructions

   

Convector Heater 
Model:  SCH5 

IMPORTANT SAFETY ADVICE 

WARNING 

–THIS  APPLIANCE  MUST  NOT  BE  USED  IN  A 

BATHROOM  

WARNING    -  DO  NOT  USE  THIS  HEATER  IN  THE  IMMEDIATE 
SURROUNDINGS  OF  A  BATH,  A  SHOWER  OR  A  SWIMMING 
POOL. 

WARNING 

–  THIS  HEATER  MUST  NOT  BE  LOCATED 

IMMEDIATELY BELOW A FIXED SOCKET OUTLET. 

FOLLOW these instructions carefully. 

NEVER  cover  or  obstruct  in  any  way  the  heat  outlet  slots  at  the 
top of the heater or the air inlet slots in the base of the heater. 
The heater carries a warning ‘DO NOT COVER’ to alert the user to 
the risk of fire that exists if the heater is accidentally covered. 

If using this heater with a programmer, timer or any other device 
that  switches  the  heater  on  automatically,  great  care  is  to  be 
taken  that  the  heater  is  not  covered  or  positioned  incorrectly 
since a fire risk could exist.  

This  appliance  is  not  intended  for  use  by  children  or  other 
persons  without  assistance  or  supervision  if  their  physical, 
sensory  or  mental  capabilities prevent  them  from  using  it  safely. 
Children  should  be  supervised  to  ensure  that  they  do  not  play 
with the appliance.  

If  young  children,  the  aged  or  infirm  are  likely  to  be  left  in  the 
vicinity of the heater, we advise that adequate precautions should 
be taken. We recommend that a guard be fitted to ensure contact 
with the heater s avoided and objects cannot be inserted into the 
product. 

If  the  supply  cord  is  damaged,  it  must  be  replaced  by  the 
manufacturer,  its  service  agent  or  similarly  qualified  persons  in 
order to avoid a hazard. 

.

 

Fig.2 

 

 

 

 

INDSUKSCH5  Issue 5   (Feb 2010) 

 

 

Heater must be horizontal with the supply cable at the 
right hand end 

110mm 

Fig.1 

Отзывы: