5. Frost Protection Programme 

A special frost protection programme can be set for longer 
periods of absence. In this mode, the heater switches on if 
the temperature recorded by the temperature sensor on the 
heater with integrated programming module is just a few °C 
above freezing. 

  Only complete days can be selected. 

  The time period which can be set is at least 1 day and 

no more than 99 days. 

  During serial use (see "1. Description"), all 

downstream heaters are also set to frost protection. 

Setting frost protection 

  Press 

 and OK buttons simultaneously for approx. 3 

seconds until "00" flashes. 

  Use 

 

 buttons to select the number of days (01 = 1 

day, 07 = 7 days) 

  Press OK to confirm. 

The number of days for frost protection mode is shown on 
the display.  
Once the set frost protection period is over, the programme 
returns to the original programme. If the frost protection 
programme is interrupted prematurely, the 

 and OK 

buttons should be pressed simultaneously for around 3 
seconds. 

 

6. Button Lock 

Press the two 

 

 buttons for 3 seconds. The key symbol 

appears on the display. The buttons are locked against 
unauthorised use. 
To cancel the button lock, press the two 

 

 buttons again 

for 3 seconds.

 

 

7. Electrical Connection 

If a programming module is to be used to control e.g. a 
complete apartment, one heater (master heater) is fitted 
with the programming module. All downstream heaters 
(slave heaters) should be linked to the master heater by a 
black control wire. 
The heating programmes set on the master heater's 
programming module are then also used by the 
downstream slave heaters. Move rotary switch on all 
heaters to "

".  

Not necessary on EPX and GFP heater types. 
A maximum of 20 slave heaters can be connected 
downstream of one master heater. 

8. Rectifying Minor Problems

 

  Programming not possible

 

 Cancel button lock if applied (see 6. Button Lock). 

 Press Prog button for around 1 second. 

Continue as described under "4.b".

 

  Nothing shown on display 

 Load programming module. 

Plug module into heater until battery is charged (takes 
around 10 mins.).

 

 
In the event of faults, please contact your electrician or your 
nearest Dimplex customer service point. 
The E number and FD number of the programming module 
and heater are needed to process the order and can be 
found on the respective type plate.

 

 

9. Cleaning 

The programming module must be removed from the heater 
before cleaning. 
The outside can be cleaned by wiping with a soft, damp 
cloth and then dried. 
Warning! Do not dampen contacts on underside! 
Do not use abrasive powder or furniture polish to clean as 
these may damage the surface and the display in particular. 
 

10. Technical Data 

Operating modes 

Comfort and Setback times can be 
set to any length, but must each be at 
least 1 hour. The frost protection 
function can be set for between 1 and 
99 days. 

Connection voltage 

1/N 230V~ 

Control signal 

230V~ via separate control wire 

Protection class II 

With protective insulation 

Degree of protection  

IP 24 With splash protection  

 

(in heater) 

Suited to heaters 

FPE, KLE, KSE, EPX and GFP

 

 

A maximum of 20 heaters can be 

 

controlled 

Display  

LCD 

Dimensions (W x H x D)  58 x 45 x 145 mm 
Weight 

0.13 kg 

 

Disposal Notice

  

The product should not be disposed of with your 
other household waste.

 

 

 

 

 
 

 

Programming module 

 

Master heater 

 

Slave heater  

 

Slave heater  

 

Control wire 

 

Max. 20 

L N PE 

 

 

Glen Dimplex Deutschland GmbH 

Tel. +49 9221 709-564 

Subject to modifications without prior notice 

Am Goldenen Feld 18  

Fax +49 9221 709-589  

www.dimplex.de 

D-95326 Kulmbach 

E-mail: [email protected] 

Содержание RMT 2

Страница 1: ...zgerät eingestellt werden Abdeckung am Raumthermostaten des Heizgerätes vorsich tig entfernen und Programmierkassette einsetzen 4 Programmierkassette einstellen Uhrzeit Wochentag Komfortbetrieb Absenkbetrieb Einstelltasten 4 a Wochentag und Uhrzeit einstellen Tasten Prog und Wochentag mit den Tasten einstellen und mit Taste OK bestätigen gleichzeitig 3 Sekunden lang drücken bis die Tagesanzeige bl...

Страница 2: ...geräten berücksichtigt Drehschalter an allen Heizgeräten auf Es können maximal 20 Slavegeräte dem Pilotgerät nachge schaltet werden stellen Nicht erforderlich an den Gerätetypen EPX GFP 8 Kleine Fehler selbst beheben Keine Programmierung möglich Eventuell Tastensperre aufheben siehe 6 Tastensperre Taste Prog ca 1 Sekunde lang drücken Wie unter 4 b beschrieben weiterverfahren keine Anzeige am Displ...

Страница 3: ...es of charging Carefully remove the cover from the heater s room thermostats and insert the programming module 4 Setting Programming Module 4 a Setting day of the week and time Press Prog and buttons simultaneously for 3 seconds until the day indicator flashes Use the buttons to set the day of the week and confirm with OK Select hour display 24 H or 12 H UK 12 hour time and confirm with OK Set the...

Страница 4: ...aximum of 20 slave heaters can be connected downstream of one master heater 8 Rectifying Minor Problems Programming not possible Cancel button lock if applied see 6 Button Lock Press Prog button for around 1 second Continue as described under 4 b Nothing shown on display Load programming module Plug module into heater until battery is charged takes around 10 mins In the event of faults please cont...

Страница 5: ...glée dans l appareil de chauffage Retirer avec protection le couvercle du thermostat d ambiance de l appareil de chauffage et mettre la cassette de programmation en place 4 Réglage de la cassette de programmation 4 a Réglage du jour de la semaine et de l heure Appuyer simultanément sur les touches Prog et pendant 3 secondes jusqu à ce que l indication du jour clignote Régler le jour de la semaine ...

Страница 6: ...appareils de chauffage sur Pas nécessaire sur les types d appareils EPX GFP Jusqu à 20 appareils esclaves peuvent être commutés en aval de l appareil pilote 8 Corriger les petits défauts soi même Programmation impossible désactiver éventuellement le verrouillage des touches voir 6 Verrouillage des touches appuyer sur la touche Prog pendant env 1 seconde Poursuivre comme décrit sous 4 b Afficheur v...

Отзывы: