FINISHED WALL
SURFACE
SIDE FLANGES
15"
[38cm]
min. 12"
[30.5cm]
3 5/8"
[9cm]
14 1/4"
[36cm]
19 3/4"
[50cm]
7/8"[22mm] DIA
KNOCKOUT
FINISH FLOOR
19 3/4"
[50cm]
14 1/4"
[36cm]
min. 12"
[30.5cm]
www.dimplex.com
2
Figure 2
Figure 3
L
L
L
WIRING
CUSTOMER
SUPPLY
BUILT-IN THERMOSTAT (FACTORY WIRED)
OFF
CYCLE
GRND.
UNIT
THERMOSTAT
L1
L2
3
2
1
M
UNIT
GRND.
S.P. "LINE" VOLTAGE REMOTE THERMOSTAT
D.P. "LINE" VOLTAGE REMOTE THERMOSTAT
GRND.
UNIT
L2
L1
A
B
FACTORY
SUPPLIED
SUPPLIED
CUSTOMER
CUSTOMER
SUPPLIED
SUPPLIED
FACTORY
B
A
L1
L2
M
1
2
3
L2
L1
THERMOSTAT
CYCLE
OFF
SUPPLY
CUSTOMER
WIRING
REMOTE
SP STAT
DP STAT
REMOTE
WIRING
CUSTOMER
SUPPLY
OFF
CYCLE
THERMOSTAT
L1
L2
3
2
1
M
L2
L1
A
B
FACTORY
SUPPLIED
SUPPLIED
CUSTOMER
NOTE:
THIS WIRING REPRESENTS THE UNIT AS FACTORY WIRED.
PLEASE CONSULT THE OTHER DIAGRAMS SHOWN AS TO
WHAT OPTION IS REQUIRED. PLEASE ASSURE THAT ALL
1. MARR/TAPE WIRE LABELLED "L1" FROM THERMOSTAT
AS SHOWN.
2. DISCONNECT WIRE "B" FROM MARR CONNECTOR "B",
REMOVE FROM THERMOSTAT CONNECTOR AND DISCARD.
3. CONNECT INCOMING SUPPLY "L1" TO CONNECTOR "A"
4. CONNECT LOAD SIDE OF REMOTE LINE VOLTAGE
THERMOSTAT TO MARR CONNECTOR "B" AS SHOWN.
5. CONNECT INCOMING POWER WIRE "L2" TO BOTH THE LINE
1. MARR/TAPE WIRE LABELLED "L1" FROM THERMOSTAT
AS SHOWN.
2. DISCONNECT WIRE "B" FROM MARR CONNECTOR "B",
REMOVE FROM THERMOSTAT CONNECTOR AND DISCARD.
3. CONNECT LOAD SIDES OF REMOTE WALL THERMOSTAT TO
MARR CONNECTORS "A" AND "B" AS SHOWN IN DIAGRAM.
CONNECTIONS MADE ARE SECURE AND THAT ALL ELECTRICAL
CLEARANCES ARE MET.
A
B
C
B
A
C
D
B
C
L1
L2
L2
L1
L1
L2
SIDE OF REMOTE WALL THERMOSTAT AND WIRE ATTACHED
TO BUILT IN THERMOSTAT WIRE LABELLED "L2" AS SHOWN.
4. CONNECT WIRE "A" TO INCOMING SUPPLY "L1".
5. CONNECT THE OTHER INCOMING POWER SUPPLY LINE TO
THE OTHER LINE SIDE OF REMOTE WALL THERMOSTAT
AS SHOWN.
D
A
D
(A) Place frame over top of tabs.
(B) Push in at bottom until frame is flush with front panel.
(C) Insert two screws to hold frame in place.
A
B
B
C
C
A