7211920100R00

Forced Air Heater

RFF Series

 WARning:  

Wiring procedures and connections should be 

in accordance with the National Electric code (NEC) and local 

codes.

!

  nOTE:  

Each heater comes as two packages: the main 

heater assembly and the associated grille kit.

  CAUTiOn: 

Do not operate heater without the Grille 

installed.

Remove the main heater assembly from the carton.  

1. 

Remove the screws securing heater assembly and retaining 

brackets to the recess box and separate. (Figure 1) 

!

  nOTE:

 Mount the heater a minimum of 12 inches (30.5 

cm) from the finished floor.

Recessed installation

The recess box provided with the heater is 

2. 

designed for attachment between studs placed on 

32 inch (81 cm) centres.  If different spacing exists, 

construct frame to suit the box in order to avoid 

any vibration and noise caused by loose mounting.

Note orientation of box (“TOP” shown on recess 

3. 

box) and secure to studs using four (4) holes 

provided on side flanges, ensuring these flanges 

are flush with finished surface of wall. (Figure 2)

Surface installation

2.  Secure optional surface mount box (Part No. 

RFFP8C) by angling screws through holes 

provided in rear of surface box into studs or 

finished surface.

3.  Position recess box into surface box and secure 

with four (4) screws provided in parts bag of 

surface box.

Supply Wiring and Heater installation

Insert approximately 15 inches (38 cm) of supply 

4. 

wire into recess box through knockout provided in 

upper left hand corner.  

Wire should be rated for a 

minimum of 90 

o

C (194 

o

F)

Connect power supply to terminals provided marked 

5. 

L1 and L2.  Ground wire should be secured to green 

ground screw provided on side of heater assembly.

All units are factory pre-wired for operation with a 

6. 

built-in thermostat.  If remote thermostat operation is 

required, follow appropriate wiring diagram located 

on inside of recess box.

!

  nOTE: 

All wiring must comply with the National Electrical 

Code and local codes.

Secure heater assembly and retaining brackets to 

7. 

the recess box using the screws that were previously 

removed.  

Front Panel installation

Remove trim frame and front panel (grille) from the carton. 

8. 

If tamper proof built-in or remote thermostat operation 

9. 

is required, secure the louvered door to the front panel 

using two (2) M3 screws (not included) through the holes 

provided.  The knob can then be removed and adjustment 

of the thermostat can be made using needle nose pliers 

through the front panel.

!

  nOTE: 

 347V/600V units come a grille which is tamper 

proof.

Install the front panel on the heater assembly.  Check to 

10. 

see that the fan blade is free to turn and that no residue 

remains in the unit.  Front panel can then be secured to 

assembly using eight (8) M4.8 x 37 screws provided.

Follow the steps as shown in Figure 3.

11. 

 installation instructions

imPORTAnT inSTRUCTiOnS

When using electrical appliances, basic precautions should 

always be followed to reduce the risk of fire, electric shock 

and injury to person, including the following: 

Read all instructions before using this heater.

1. 

A heater has hot and arcing or sparking parts inside.  Do 

2. 

not use it in area

s where gasoline, paint or flammable 

liquids are used or stored.

This heater is hot when in use.  To avoid burns, do not let 

3. 

bare skin touch hot surfaces.  If provided, use handles 

when moving this heater.  Keep combustible materials 

such as: furniture, pillows, bedding, papers, clothes and 

curtains away from heater.

To prevent a possible fire, do not block air intakes or 

4. 

exhaust in any manner.  Do not use on soft surfaces like a 

bed where openings may become blocked.

Do not insert or allow foreign objects to enter any venti-

5. 

lation or exhaust opening as this may cause an electric 

shock or fire, or damage the heater.

SAvE THESE inSTRUCTiOnS

Figure 1

Figure 2

Recess Box

Heater

Assembly

Finished Wall

Surface

15” (38 cm)

Side Flanges

Finished Floor

30”

(76 cm)

7/8” (22 mm) 

Dia. Knockout

19 3/4”

(50 cm)

3 5/8”

(9 cm)

Min. 12”

(30.5 cm)

!

  nOTE:

 

 Dimensions are shown as size 

of rough opening in stud wall.