Touch Pad Replacement

Tools Required:

  Phillips head screwdriver

   WARNING:

  If the firebox was operating prior to 

servicing, allow at least 10 minutes for the heating 

elements to cool off to avoid accidental burning of skin.

   WARNING:

  Disconnect power before attempting any 

maintenance to reduce the risk of electric shock or 

damage to persons.

1.  Unplug the fireplace or turn off the breaker to 

disconnect the power.

2.  Remove the front glass.
3.  Remove the two screws on each side of the touch pad 

assembly.

4.  Unplug the pin connector.
5.  Plug in the connector from the new touch pad.
6.  Install the replacement control assembly and secure 

with the 4 screws that were previously removed.

7.  Reinstall the front glass.

Thermistor Replacement (RBF24DLX)

Tools Required:

  Phillips head screwdriver

1.  Follow the steps of ‘Preparing for Service” on page 8.
2.  Remove the 2 hex head screws on either side of the 

controls and the 4 hex head screws (12 screws total)  

along each side of the panel and gently lower the 

internal assembly. (Figure 4)

3.  Disconnect the two main wire connectors - one on each 

side of the unit.

4.  Disconnect the hanging straps at the front, ensuring 

that you support the entire assembly, and lift the back 

of the assembly up and off of the hook at the back.  At 

this point you should be able to gently set the assembly 

on the surface in front of the unit to replace the heater 

assembly.

5.  Trace the thermistor wire back to the main board, 

cutting the cable ties as necessary. Unplug the 

defective thermistor.

6.  Hold the top and bottom parts of the thermistor 

housing, twisting them until they come apart. 

 

(Figures 5 and 6)

7.  Remove the thermistor from the thermistor housing.
8.  Insert the new thermistor into the thermistor housing.
9.  Secure the thermistor housing to the top panel.
10. Connect the new thermistor to the main control board.
11.  Reassemble the remainder of the firebox in reverse 

order from the instructions above.

Front Top 

Lights

Rear Top 

Lights

Power Supply 

Bracket Screws

Heater Assembly Bracket 

Screws 

(RBF24DLX)

Touch Pad 

Screws

Outer Thermistor Housing 

(RBF24DLX)

Figure 6

Содержание Revillusion RBF24DLX

Страница 1: ...6909790100 6909790200 6909800100 7400970000R02 IMPORTANT SAFETY INFORMATION Always read this manual first before attempting to service this firebox For your safety always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage ...

Страница 2: ...m RBF24DLX 9 Replacement Parts List 9 Wiring Diagram RBF30 RBF36 RBF36P RBF42 10 Wiring Diagram RBF24DLX 10 Preparing for Service 11 Ember LED Light Replacement 12 Flame Base LED Replacement 12 Flame LED Replacement 12 Flicker Motor Replacement RBF30 RBF36 RBF36P RBF42 12 Flicker Motor Replacement RBF24DLX 12 Main Control Board Replacement 13 Power Supply Replacement 13 Blower Assembly Replacement...

Страница 3: ...f the built in electric firebox Icon Function Description A Power Standby Press to activate the current standby state On Off Standby State On Press to turn everything Off Press again to activate the previous state Standby State Off Press to activate the previous state If the flame effect was On the previous heat setting will be activated On or Off If the flame effect was Off the previous heat sett...

Страница 4: ... is ON G Brightness Press to change the LED lights from High to Low The last segment on the display will change from H to L The RealogTM LEDs remain On when the heater is ON and the flame effect is Off NOTE When the Light Sensor is activated High and Low flickering brightness settings are also available Flashing H and L H Flame Press to light the log set and start the flame effect Press again to t...

Страница 5: ...he log set and start the flame effect Press again to turn feature Off C Temp Down Press multiple times to lower the heater temperature in 1 F 1 C increments Displays current temperature lowest temperature is 41 F 5 C This feature is active whenever the heat is enabled Icon Function Description D Flame Speed Press multiple times to toggle through the flame speeds minimum medium maximum The display ...

Страница 6: ...on the display ECO is indicate by an Eco on the display and Boost is indicate by a b20 on the display In boost mode a time is set initial for 20 minutes and the display will indicate b19 b18 etc as the time counts down This is shown by pressing the heat mode button K Temp Up Press multiple time to raise the heater temperature in 1 F 1 C increments Displays current temperature highest temperature i...

Страница 7: ... firebox Never use abrasive cleaners Clean Reflector Screen The reflector screen is cleaned in the factory during the assembly operation During shipment installation handling etc the screen may collect dust particles these can be removed by dusting lightly with a clean dry cloth To remove fingerprints or other marks clean the reflector screen damp cloth Never use abrasive cleaners Dry the screen c...

Страница 8: ...RBF30 3001760200RP RBF36 RBF36P RBF42 3001760300RP 12 Ember LED RBF30 3001820100RP RBF36 RBF36P RBF42 3001820200RP 13 Top Back Light RGB 3001570100RP 14 Top Front Lights 2 sets RBF30 3001570600RP RBF36 RBF36P 3001570500RP RBF42 3001570401RP 15 Flame Screen RBF30 5903010100RP RBF36 5903020100RP RBF36P 5903020300RP RBF42 5903020200RP 16 Log Set Assembly RBF30 0442100100RP RBF36 RBF36P RBF42 04421101...

Страница 9: ...od 5903040200RP 7 Remote Control 3001970100RP 8 Thermistor 0442570100RP 9 Flame Base RGB 3001790100RP 10 Flame Back Log LED 3001760200RP 11 Ember LED 3001820100RP 12 Top Back Light RGB 3001570100RP 13 Top Front Lights 2 sets 3001570600RP 14 Flame Screen 5903010200RP 15 Log Set Assembly 0442400100RP 16 Brick Panels LH RH 5903200001RP 17 Weather Concrete Panels LH RH 5903201001RP 18 Front Glass 6909...

Страница 10: ...rt T7 ACN CN12 FAN1 T8 L in IC6 CN7 CN4 NTC CN2FLAME CN6 Control Panel MOT CN3FLAME CN1 12V T2 HTR2 T1 L2 RY4 T4 HTR1 CN11 T BK RGB CN10 T FR RGB CN9 FLAME RGB T3 L1 PZ2 HT EN E5 E1 L1 T9 ACN G 4 G 2 J P 6 R 2 4 1 K D 1 R 1 2 2 K G 1 R 1 1 4 7 0 R 1 3 2 K 0 A P 2 9 5 2 C 1 2 1 0 3 R 1 1 0 0 K C 9 1 0 4 C 1 0 1 0 4 R 2 7 2 K H T R 2 H T R 1 FAN1 FAN2 N CONTROL PANEL ...

Страница 11: ...dle the log set by the plastic grate not the logs themselves 4 Slide the log set assembly forward and lift the log set assembly and the ember mat out Figure 3 NOTE If using the original log set assembly it must be unplugged to remove it 5 On either side of the firebox gently remove the decorative panels by placing your finger in the gap toward the back and pulling out The decorative panels are hel...

Страница 12: ...marked J1 is on the left hand side 8 Reassemble the unit in reverse order from the instructions above Flicker Motor Replacement RBF30 RBF36 RBF36P RBF42 Tools Required Phillips head screwdriver 1 Follow the steps of Preparing for Service on page 8 2 Remove the back log assembly by removing the two screws along the front of the log and the screw on either end 3 On the left hand side locate the moto...

Страница 13: ...in cable ties Power Supply Replacement Tools Required Phillips head screwdriver 1 Follow the steps of Preparing for Service on page 8 2 Remove the 2 hex head screws on either side of the controls and the 4 hex head screws 12 screws total along each side of the panel and gently lower the internal assembly Figure 4 3 Disconnect the two main wire connectors one on each side of the unit 4 Disconnect t...

Страница 14: ...tact with moving parts by securing wires in cable ties Element Replacement RBF30 RBF36 RBF36P RBF42 Tools Required Phillips head screwdriver Flat Head Screwdriver 1 Follow the steps of Preparing for Service on page 8 2 Remove the 2 hex head screws on either side of the controls and the 4 hex head screws 12 screws total along each side of the panel and gently lower the internal assembly Figure 4 3 ...

Страница 15: ...X Tools Required Phillips head screwdriver Flat Head Screwdriver 1 Follow the steps of Preparing for Service on page 8 2 Remove the 2 hex head screws on either side of the controls and the 4 hex head screws 12 screws total along each side of the panel and gently lower the internal assembly Figure 4 3 Disconnect the two main wire connectors one on each side of the unit 4 Disconnect the hanging stra...

Страница 16: ...crews total along each side of the panel and gently lower the internal assembly Figure 4 3 Disconnect the two main wire connectors one on each side of the unit 4 Disconnect the hanging straps at the front ensuring that you support the entire assembly and lift the back of the assembly up and off of the hook at the back At this point you should be able to gently set the assembly on the surface in fr...

Страница 17: ...m the instructions above Top Front Lights Replacement Tools Required Phillips head screwdriver 1 Follow the steps of Preparing for Service on page 8 2 Remove the 2 hex head screws on either side of the controls and the 4 hex head screws 12 screws total along each side of the panel and gently lower the internal assembly Figure 4 3 Locate the defective front top light assembly From the backside of t...

Страница 18: ... turn on in Remote Mode Improper operation Refer to Operation section Loose wiring Check wiring connections Remote control not working Replace batteries Replace remote control if defective Defective touch pad Replace touch pad Defective main control board Replace main control board One or all logs in log set dim not glowing Loose connection Check wiring connections Defective log set Replace log se...

Страница 19: ...n unit Defective heater assembly Replace heater assembly Heating element is glowing red Normal Operation Small glowing sections of the element are considered normal Defective blower If larger glowing sections are causing the heater to trip the thermal cutout unplug unit discontinue use and replace blower heater assembly Defective heater assembly Heater fan runs continuously Defective main control ...

Отзывы: