Operation
Figure 2
A - Setting/Temperature Display
B - Economy Setting Icon
C - Set Back Temperature Setting
D - Comfort Setting Icon
E - Synchronized Icon
F - Lock Icon
G - Decrease Button
H - Increase Button
I - Menu Button
CAUTION:
This panel convector must be properly
installed before it is used.
CAUTION:
Prior to energization remove all construction
dirt (plaster, sawdust, etc.) from interior and exterior of panel
convector.
CAUTION:
Avoid direct contact of paper, fabric, or
furniture with panel convector, to prevent a possible fire.
Dimplex panel convectors are designed and tested for safe
and trouble-free operation. Free airflow throughout the panel
convector is very important for the most efficient operation
of the panel convector. All Dimplex panel convectors are
protected against overheating by a built-in thermal cutout.
A thermal cutout will switch off the heater if for any reason
it overheats. Should the cutout operate, disconnect heater
from power supply and determine the reason for overheating.
Resolve the reason for overheating before attempting to use
the heater again. To reset the heater it is necessary to switch
off the power to the heater for several minutes.
The PPC features CONNEX
TM
, a wireless technology that
works with Dimplex single and multi-zone CONNEX
TM
controllers to provide simple whole home connectivity and
comfort. CONNEX
TM
controllers are available to control one
or multiple CONNEX
TM
heaters within a 50 ft. (15 m) radius.
When power is first supplied to the PPC the Setpoint
Temperature will flash in the temperature display area. At
any time either the
+
or
�
button can be pressed to have the
temperature setpoint displayed again.
A. Setting/Temperature Display
The PPC is designed to control the temperature of a room
anywhere from 32-86°F (0-30°C). Pressing the
+
or
�
will
increase or decrease the desired temperature for the room to
be heated by 0.5° (in either °C or °F).
After 5 seconds the Setpoint Temperature will switch to
display the intake temperature of the room.
!
NOTE:
Pressing the
+
and
�
at the same time will toggle
between °C and °F.
B. Economy Setting
The Economy Setting can be used to change the Setpoint
Temperature for a variable period of time. By pressing the
V
the Economy Setting will be enabled - signified by the icon
flashing. After the Set Back Temperature has been set, the
icon will become solid after three seconds and the Set Back
Temperature will be enabled.
To return back to the Comfort Setting press the
V
button and
the icon will disappear and the icon will appear.
C. Set Back Temperature Setting
The Set Back Temperature Setting is used during periods
when the Economy setting feature is active. This temperature
adjustment can be set by pressing the
V
followed by the
+
or
�
.
D. Comfort Setting
The Comfort Setting icon will be displayed when the heater
is in normal operation based on the Setpoint Temperature for
the room.
!
NOTE:
Either the or icon will always be visible,
dependent on the setting being used.
E. Synchronized Icon
The PPC and the controller will need to be synchronized, to
operate together. To do this:
1. On the PPC heater press and hold the
V
button for 3
seconds, both the
and icons will begin to flash.
2. Press the
�
,
+
and then
V
, on the PPC heater.
3. Within 10 seconds press any button once on the
CONNEX
TM
controller.
!
NOTE:
There is a 3 second delay between pressing the
last button the CONNEX
TM
controller and the PPC heater.
!
NOTE:
To desynchronize a PPC heater from the
synchronized CONNEX
TM
controller, on the PPC heater:
1. Press and hold the
V
for 3 seconds.
2. Press the
V
,
+
and then
�
.
Nothing needs to be done to the CONNEX
TM
controller.
Dimplex single and multi-zone CONNEX
TM
controllers are
sold separately and are available for purchase from your
authorized Dimplex dealer.
To find your local Dimplex dealer, visit www.dimplex.com.
Wiring Diagram
L2
L1
Ground
Thermal Cutout
Temperature
Sensor
Electrical Connection
WARNING:
Heater and controls should be installed by a
qualified contractor. Wiring procedures and connections
should be in accordance with the National Electric Code
(CEC & NEC) and local codes.
Connect the supply wire into a properly rated recess box.
!
NOTE:
Consult your local electrical code for applicable
wire gauge.
Connect L1 from the power supply to the L1 labelled wire
from the unit, connect the L2 wire from the power supply to
the L2 labelled wire from the unit, and connect the ground to
the ground screw on the unit.
B
E
F
G
H
I
A
C
D