 Operation

Figure 2

A - Setting/Temperature Display

B - Economy Setting Icon 

C - Set Back Temperature Setting

D - Comfort Setting Icon

E - Synchronized Icon

F - Lock Icon

G - Decrease Button

H - Increase Button

I - Menu Button

 CAUTION: 

This panel convector must be properly 

installed before it is used.

 CAUTION: 

Prior to energization remove all construction 

dirt (plaster, sawdust, etc.) from interior and exterior of panel 

convector.

 CAUTION:

 Avoid direct contact of paper, fabric, or 

furniture with panel convector, to prevent a possible fire.
Dimplex panel convectors are designed and tested for safe 

and trouble-free operation. Free airflow throughout the panel 

convector is very important for the most efficient operation 

of the panel convector. All Dimplex panel convectors are 

protected against overheating by a built-in thermal cutout. 

A thermal cutout will switch off the heater if for any reason 

it overheats. Should the cutout operate, disconnect heater 

from power supply and determine the reason for overheating. 

Resolve the reason for overheating before attempting to use 

the heater again. To reset the heater it is necessary to switch 

off the power to the heater for several minutes. 
The PPC features CONNEX

TM

, a wireless technology that 

works with Dimplex single and multi-zone CONNEX

TM

 

controllers to provide simple whole home connectivity and 

comfort. CONNEX

TM

 controllers are available to control one 

or multiple CONNEX

TM

 heaters within a 50 ft. (15 m) radius. 

When power is first supplied to the PPC the Setpoint 

Temperature will flash in the temperature display area. At 

any time either the 

+

 or 

� 

button can be pressed to have the 

temperature setpoint displayed again.

A. Setting/Temperature Display

 

The PPC is designed to control the temperature of a room 

anywhere from 32-86°F (0-30°C). Pressing the 

+

 or 

 will 

increase or decrease the desired temperature for the room to 

be heated by 0.5° (in either °C or °F).
After 5 seconds the Setpoint Temperature will switch to 

display the intake temperature of the room.

!

 NOTE: 

Pressing the

 

+

 and 

 at the same time will toggle 

between °C and °F.

B. Economy Setting

 

The Economy Setting can be used to change the Setpoint 

Temperature for a variable period of time. By pressing the 

V

 

the Economy Setting will be enabled - signified by the icon 

flashing. After the Set Back Temperature has been set, the 

icon will become solid after three seconds and the Set Back 

Temperature will be enabled.
To return back to the Comfort Setting press the 

V

 button and 

the   icon will disappear and the   icon will appear. 

C. Set Back Temperature Setting

 

The Set Back Temperature Setting is used during periods 

when the Economy setting feature is active. This temperature 

adjustment can be set by pressing the 

V

 followed by the 

+

 or 

D. Comfort Setting

 

The Comfort Setting icon will be displayed when the heater 

is in normal operation based on the Setpoint Temperature for 

the room.

!

 NOTE:

 Either the   or   icon will always be visible, 

dependent on the setting being used.

E. Synchronized Icon

 

The PPC and the controller will need to be synchronized, to 

operate together. To do this:
1.  On the PPC heater press and hold the 

V

 button for 3 

seconds, both the 

 and   icons will begin to flash.

2.  Press the 

 , 

+

 and then 

V

, on the PPC heater.

3.  Within 10 seconds press any button once on the 

CONNEX

TM

 controller.

!

 NOTE:

 There is a 3 second delay between pressing the 

last button the CONNEX

TM

 controller and the PPC heater.

!

 NOTE:

 To desynchronize a PPC heater from the 

synchronized CONNEX

TM

 controller, on the PPC heater:

1. Press and hold the

 V

 for 3 seconds.

2. Press the 

V

+

 and then 

.

Nothing needs to be done to the CONNEX

TM

 controller.

Dimplex single and multi-zone CONNEX

TM

 controllers are 

sold separately and are available for purchase from your 

authorized Dimplex dealer.
To find your local Dimplex dealer, visit www.dimplex.com.

Wiring Diagram

L2 

L1 

Ground 

Thermal Cutout

Temperature
Sensor

Electrical Connection

   WARNING: 

Heater and controls should be installed by a 

qualified contractor. Wiring procedures and connections 

should be in accordance with the National Electric Code 

(CEC & NEC) and local codes. 

Connect the supply wire into a properly rated recess box.

!

 NOTE: 

Consult your local electrical code for applicable 

wire gauge.
Connect L1 from the power supply to the L1 labelled wire 

from the unit, connect the L2 wire from the power supply to 

the L2 labelled wire from the unit, and connect the ground to 

the ground screw on the unit.

B

E

F

G

H

I

A

C

D