background image

Model

Description

Watts

OFC12

5 Fin, Thermostat, 2 Heat Settings, Neon

1200

OFC12TI

5 Fin, Thermostat, 2 Heat Settings, Neon, Electronic Timer

1200

OFC15

7 Fin, Thermostat, 2 Heat Settings, Neon

1500

OFC15TI

7 Fin, Thermostat, 2 Heat Settings, Neon, Electronic Timer

1500

OFC20

9 Fin, Thermostat, 2 Heat Settings, Neon

2000

OFC20TI

9 Fin, Thermostat, 2 Heat Settings, Neon, Electronic Timer

2000

OFC25

11 Fin, Thermostat, 2 Heat Settings, Neon

2500

OFC25TI

11 Fin, Thermostat, 2 Heat Settings, Neon, Electronic Timer

2500

Important Safety Advice

If the appliance is damaged, check immediately with the supplier
before installation and operation.

Warning – This appliance must not be used in a bathroom.

Warning – Do not use this heater in the immediate surroundings
of a bath, a shower or a swimming pool.

Warning – This heater must not be located immediately below a
fixed socket outlet.

Warning – Do not use in areas where petrol, paint or flammable
liquids are used or stored.

Follow these instructions carefully.

The heater carries a warning ‘Do Not Cover’ to alert the user to
the risk of fire that exists if the heater is accidentally covered.

The appliance is not intended for use by children or other persons
without assistance or supervision if their physical, sensory or
mental capabilities prevent them from using it safely. Children
should be supervised to ensure that they do not play with the
appliance.

If the mains lead is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified person
in order to avoid a hazard.

Unplug the heater when not required for long periods.

Do not use the heater if it develops a leak. Unplug the heater and
contact your supplier or the manufacturer’s service agent.

Momentary contact with any part of the heater should not cause
injury. However aged, infirm persons or young children should
not be left unsupervised in the vicinity of the heater.

Please Note – We recommend that you open a window to ventilate
the room when using the heater for the first time.

THE HEATER CARRIES THE WARNING SYMBOL INDICATING
THAT IT MUST NOT BE COVERED.

General

The radiator is designed for operation on an AC electricity supply, and is
suitable for use in domestic dwellings and similar indoor locations.
Always ensure that the appliance is stood on a firm, level base near to,
but not directly beneath, a suitable fixed socket outlet.
The radiator is fitted with castors and a handle for ease of movement.
Selector switches provide a choice of heat output and an adjustable
thermostat enables the room temperature to be controlled accordingly. It
is supplied with a cord and plug ready for use.
The supply cord should be uncoiled before use (see ‘Storage’).
DO NOT pull the radiator along by the mains lead.

Important - 

The radiator must only be operated with the wheels and

castors fitted and in the upright position as shown in 

Fig. 1

.

Warning – The heater complies with stringent safety standards but to
ensure efficient operation 

SURFACES OF THE HEATER WILL BECOME

HOT AND CONTACT WITH THESE AREAS SHOULD BE AVOIDED,

particularly between the fins on the top and sides.
The control panel area is designed to be at a far lower temperature to
allow the safe operation of the controls at any time.

Electrical

WARNING – THIS APPLIANCE MUST BE EARTHED

If the socket outlets in your home are not of the 13 amp BS1363 type they
will not accept the plug connected to this heater,  therefore cut off the
plug.  When cut off this plug can constitute a shock hazard if inserted into
a socket outlet.  It must therefore be disposed of safely.

Before wiring the appropriate plug please note that the wires in this
mains lead are coloured in accordance with the following code:

GREEN/YELLOW :

 EARTH

BLUE :

NEUTRAL

BROWN :

LIVE

Connect the Green/Yellow wire to the terminal marked E or the earth
symbol or coloured Green or Green/Yellow.
Connect the Brown wire to the terminal marked L or coloured Red.
Connect the Blue wire to the terminal marked N or coloured Black. 

DO

NOT 

connect the Brown (Live) or the Blue (Neutral) wires to the Earth

terminal of your 13 amp plug.  If the terminals of the plug are unmarked
or you are in any doubt, consult a qualified electrician.

Fitting the castors

Remove the carton containing the castor assemblies from the packing.
Fit the castors to the stub axles by applying hand pressure until each
castor clicks into position - see 

Fig. 3

. Note that the castors are designed

to be a tight fit on the axles but will rotate in use.
The castors can only be fitted between the outer fins (as shown in 

Fig. 2

).

Turn the radiator upside down on a carpet or other soft surface to avoid
damage

WARNING : THE RADIATOR IS HEAVY – ENSURE THAT IT IS SUPPORTED
TO PREVENT IT FROM TOPPLING. 

Ask a second person to help with this

if necessary. Position castor bracket (see 

Fig. 3

) onto the threaded pins on

the control panel. Place the winged nut ‘C’ on the thread and tighten it
securely.
Repeat the process for castor bracket ‘B’ onto the last fin.
Note: The 5 fin column radiator models - OFC12 & OFC12TI use curved
castor brackets and must be fitted as shown in 

Fig. 2

.

Lift the radiator clear of the floor, then turn it back upright and stand it on
its castors as shown in 

Fig. 1

. It is now ready for use.

Positioning the Heater

Select the position for the radiator ensuring there is clearance from any
furniture and fittings of at least 300mm above the heater and 150mm
each side. The radiator should only be operated on a flat stable surface.

Operation

IMPORTANT

 – Objects or clothing must not be placed on this heater.

Before using the heater ensure that all warnings and instructions have
been read carefully.
To bring the heater into use plug it in. Neon indicating lights located at
the controls area will glow when the appliance is plugged into the mains.

Controls

Thermostat 

(see 

Fig. 4

)

The Thermostat (see 

Fig. 4

) controls the heat output according to the

room temperature. This ensures that the heater will not produce heat
unnecessarily when the room is warm. To set the temperature you require,
turn the thermostat knob clockwise until the required setting is reached.
Alternatively to heat a cold room quickly, turn the thermostat knob up
fully. When the room has reached the desired temperature, turn the
thermostat knob anti-clockwise until the thermostat just clicks off. The
heater will now automatically operate at this temperature. The thermostat
also has a frost protection setting marked ‘

‘. This setting is useful in

areas such as garages, to prevent frost damage. If the thermostat is set to
its minimum setting ‘

’, the heater will cycle on and off to maintain a

temperature of approximately 5° to help protect against frost.

Note –

 Should the heater fail to come on when the thermostat is at a low

setting, this may be due to the room temperature being higher than the
thermostat setting.

Heat Selector Switches 

(see 

Fig. 5

)

Selector switches located on the control panel provide a choice of heat
output to suit varying conditions and for economy of operation.

Table 1

Model

Switch 

Switch 

OFC12/OFC12TI

650W

1200W

OFC15/OFC15TI

900W

1500W

OFC20/OFC20TI

1200W

2000W

OFC25/OFC25TI

1500W

2500W

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE

Dimplex Oil filled Column Radiators

Models : OFC12, OFC12TI, OFC15, OFC15TI, OFC20, OFC20TI, OFC25 & OFC25TI