background image

D

255 Min.

C

  

     

  D

MFP500      390 

300

MFP750      390 

300

MFP1000     560 

300

MFP1500     630 

300

MFP2000     800 

300

 

‘x’

MAX

*

General

The heater is designed for wall mounting on the wall bracket
supplied. It should only be operated when in the upright
position as shown - see 

Fig. 1

.

All models are splashproof to IPX4 standard and may be
used in bathrooms, however not in the immediate vicinity of
baths, showers, water connections, wash basins or
swimming pools.
Before connecting the heater check that the supply voltage is
the same as that stated on the heater.

Wall Mounting

IMPORTANT

 – The wall bracket supplied with the appliance

must be used. The heater should be positioned observing
the minimum clearances stated around the heater - see

Fig. 1

.

DO NOT

 locate the heater immediately below a fixed socket

outlet or connection box.

1.

Remove wall mounting bracket from the back of the
heater by depressing the spring latch at the top of
each bracket - see 

Fig. 2

.

2.

Fix the wall bracket securely to the wall through the
four screw holes provided.

3.

Present the heater to the wall bracket, and engage
lower slots in the back with bracket.

4.

Raise the heater to upright position and push the
heater onto bracket to engage top latch.

Operation

Switching On the Heater 

(see 

Fig. 3

)

The controls are located on the right hand side on top of the
appliance, lift flap to access the controls - see 

Fig. 3

.

The button marked ‘

’ controls the electricity supply to the

electronic thermostat. An indicator beside the ‘

’ button

shows when the unit is powered ‘ON’.

Fig. 2

Fig. 3

Setting Desired Temperature 

(see 

Fig. 4

)

The heater is fitted with an adjustable thermostat enabling
the room temperature to be controlled by adjusting the slider
accordingly. The min setting ‘

’ represents a room

temperature of approximately 5

0

C and may be used for

protection against frost. The ‘MAX’ setting represents a room
temperature of approximately 30

0

C. The ‘ ’ symbol glows

when the elements are actually heating.

Turn on the heater using the ‘

’ button and move the

thermostat slider to the desired position. When the room
temperature has reached the desired level, the power to the
elements will be reduced, the heater will then maintain the
room temperature at the chosen level.

NOTE

 -  Should your heater fail to come on when the

thermostat slider is at a low setting, this may be due to the
room temperature being higher than the thermostat setting.

Background Temperature

When used in conjunction with a remote programming device
supporting a background/setback setting, the heater will
automatically operate at a room temperature setting of  5

0

C

less than the thermostat setting when the programme is in
background/setback mode.

Limiting the thermostat setting

Before wall mounting the product the installer may wish to
limit the heat selection slider movement for the operator.
This may be achieved by removing the two plastic pins (see
‘x’ in 

Fig. 5

) from the rear of the thermostat moulding using

pliers and inserting them in the preferred holes to limit the
slider movement.

Fig. 5

Fig. 4