Installation and Operating Instructions
IRX Range—Wall Mounted Infra Red Heater
Models: IRX1200N, IRX1800N
November 2007—Issue 4
Dimensions (mm)
Model
Length
Height
Depth
IRX1200
750
91.5
75
IRX1800N
510
140
80
Model IRX1200N
Model: IRX1800N
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
IMPORTANT SAFETY ADVICE
WARNING- This product must be installed by a competent
person or electrician in conjunction with the current IEE
Wiring Regulations and relevant Building Regulations
When using electrical appliances, basic precautions
should always be followed to reduce risk of fire, electrical
shock, and injury to persons including the following:
If aged or infirm persons or young children should not be
left unsupervised in the vicinity of the heater unless a
suitable guard is fitted This appliance is not intended for
use by children or other persons without assistance or
supervision if their physical, sensory or mental
capabilities prevent them from using it safely.
DO NOT cover or obstruct any part of the heater
DO NOT recess the unit in to a wall, as this will cause
overheating and potentially be a fire risk
The wall bracket provided must be used for
installation
DO NOT use outdoors
DO NOT locate the heater immediately below a fixed
socket outlet or connection box
This heater is IPX4 rated and can be installed in a
bathroom but must be located so switches and other
controls cannot be touched by a person using a bath
or shower
This heater should be positioned observing all safety
clearances stated in these instructions
Model
Output
(kW)
Voltage
Weight
(kg)
Finish
IP Rating
IRX1200
1.2
230V- 240V~AC
2.0
Silver
IPX4
IRX1800N
1.8
230V- 240V~AC
2.1
White
IPX4
General Principle
The IRX range of infra-red wall heaters are a safe, practical source of heat in
bathrooms, kitchens, work areas– anywhere where fast localised heating is
required.
Electrical Connection
WARNING THIS APPLIANCE MUST BE EARTHED
Before undertaking any installation work, ensure the electricity supply is
disconnected from any relevant fixing wiring.
Supply cable is not supplied with this appliance and it should therefore be installed
by a competent person or electrician and be in strict accordance with the current
IEE Wiring Regulations and relevant Building Regulations.
If in doubt consult a qualified electrician.
The supply circuit must be adequate for the input of the appliance and must be
protected wit a 13 Amp fuse.
A suitable termination to the fixed wiring of the premises must be provided adjacent
to the final position of the appliance and be not less than 1800mm from the floor,
through a double pole switch having a contact separation of at least 3mm in all
poles.
Installation
The heater should be permanently wall mounted and installed in conjunction with
the following minimum clearances:
Side clearance to wall = 200mm
Side clearance curtains or other combustible materials = 600mm
Floor to underside of heater = 250mm
See also
Fig.1
below
Technical Specification