Dimplex GDC12RBA Скачать руководство пользователя страница 8

TROUBLE SHOOTING

 

Never try to repair or dismantle the air conditioner yourself. Unauthorized repairs may 

result in the loss of warranty and can endanger the user and the property.   

Problem Cause 

Solution 

No power supply. 

Connect to a functioning outlet 

and switch on.

 

The alarm light is on. 

Empty the internal water 

container. 

The air 

conditioner does 

not function. 

Timer function is active. 

Deactivate TIMER function. 

In direct sunlight. 

Close curtains.

 

Windows or doors open, 

many people or a heat 

source in the room.   

Close doors and windows, place 

an extra air conditioner. 

Dirty filter

 

Clean the filter(s). 

Air inlet or air outlet blocked. 

Remove the blockage. 

The air 

conditioner does 

not seem to 

perform.

 

Room temperature lower 

than the selected value.

 

Change temperature selection.

 

The unit is noisy.

 

Unit is not level. 

Place on an even, solid surface 

(less vibrations.)

 

The compressor 

does not work.

 

The overheat protection is 

probably activated. 

Wait 30 minutes until the 

temperature has decreased, then 

turn the unit on again.

 

Distance too long.

 

Remote control signal not 

detected by the control 

panel.

 

Make sure the remote control is 

correctly aimed at the control 

panel.

 

The remote 

control does not 

function. 

 

The batteries are drained

 

Replace the batteries.

 

To correct problems not mentioned in the table and/or if the recommended solutions fail 

to solve the problem, please contact an authorized service centre.

 

Please contact Glen Dimplex for your nearest authorized service agent: 

Australia – 1300 556 816  New Zealand – (09) 274 8265 

SPECIFICATIONS 

Model No. 

GDC9RWA GDC12RWA 

GDC12RBA 

Power Source 

220-240V~ 50Hz AC 

220-240V~ 50Hz AC 

Power Consumption 

(EN14511) 

1080W 1452W 

Rated Power 

(EN60335) 

1250W 1480W 

Cooling Capacity 

2600W 

3500W 

Air Flow 

400 M

3

/H 420 

M

3

/H 

Moisture Removed 

32 L/DAY 

50 L/DAY 

Refrigerant R410A 

R410A 

Min. room size 

10m

2

 10m

2

 

Dimensions (mm) 

476W x 358D x 840H 

476W x 358D x 840H 

Net Weight 

28.5KG 

29.5KG 

Model No. 

GDC12RCWA / GDC12RCBA 

GDC14RWA / GDC14RBA 

Power Source 

220-240V~ 50Hz AC 

220-240V~ 50Hz AC 

Power Consumption 

Cooling / Heating 

(EN14511) 

 

1452W / 1452W 

 

1660W

 

Rated Power 

(EN60335) 

 

1480W 

 

1700W 

Cooling Capacity 

3500W 

4000W 

Heating Capacity 

3500W 

N/A 

Air Flow 

420 M

3

/H 450 

M

3

/H 

Moisture Removed 

50 L/DAY 

60 L/DAY 

Refrigerant R410A 

R410A 

Min. room size 

10m

2

 10m

2

 

Dimensions (mm) 

476W x 358D x 840H 

476W x 358D x 840H 

Net Weight 

30.5KG 

31.5KG 

Содержание GDC12RBA

Страница 1: ...ned off please wait at least 3 minutes before restarting it This is to prevent the compressor from being damaged 7 This unit needs to be plugged into a 10 Amp power point Please do not use any extensi...

Страница 2: ...eated air system design heats instantly whenever you want it Powerful dehumidification process and filtered air cycle for improved breathing conditions If the remote control function is not required y...

Страница 3: ...it is pressed to a maximum of 30 4 TEMPERATURE REGULATION KEY DOWN This key lowers the preset temperature by 1 each time it is pressed to a minimum of 17 In normal conditions the temperature data whi...

Страница 4: ...Indicates the water is full inside Please contact an authorized service centre if any of the above error messages are shown cally after the set time is over 8 SLEEP CONTROL When setting the sleep com...

Страница 5: ...r Reverse cycle Cooling Heating models only GDC12RCWA GDC12RCBA GDC14RCWA GDC14RCBA This unit can evaporate the condensation and flow out through the exhaust hose automatically when the unit is in the...

Страница 6: ...se follow the arrow direction and push the filter lightly Then take out the filter for cleaning POWER SUPPLY 1 Confirm the correct power 2 Insert the plug into the power outlet firmly In case of a dan...

Страница 7: ...the unit is not placed against objects which will obstruct air intake e g furniture or curtains as this will affect it s performance drastically Do not place the unit in direct sunlight as this may c...

Страница 8: ...he control panel Make sure the remote control is correctly aimed at the control panel The remote control does not function The batteries are drained Replace the batteries To correct problems not menti...

Страница 9: ...10m 2 Dimensions mm 476W x 358D x 840H Net Weight 32 5KG If you have any issues with your unit please contact Glen Dimplex for your nearest service agent Proof of purchase is required at the time of s...

Отзывы: