INSTALLATION  INSTRUCTIONS

FAN/BOOST
CIRCUIT

STORAGE CIRCUIT

PREPARATION

The heater will arrive separately
from its storage bricks, the
following bricks will be required.

FXL18N - 12 bricks
FXL24N - 16 bricks

Two supplies are required for the
operation of this heater - a restricted Off
Peak or Economy 7 supply for the storage
circuit, and an unrestricted supply for the
fan boost element circuit.

Thermostatic fan / boost control is
provided on the heater, however the fan /
boost operation may be customised by
the introduction of an external timer to
the heater (see section 3).

WARNING - This appliance

must be earthed

Only heat resisting cable (min. rating T85)
should be used.  The wires in the mains
cable will be coloured as follows:-

GREEN & YELLOW - EARTH

BLUE - NEUTRAL

BROWN - LIVE

SUGGESTED FIXINGS

SOLID BRICK/BLOCK

No. 10 Rawlplug fibre inserts, 5.5mm drill

bit.  Drill hole 10mm deeper than rawlplug

length.

PLASTERBOARD

If possible locate studding and use No. 10

woodscrews directly into the wood,

otherwise M5 rawlplug intersets are

suitable.

NOTE: FOR OTHER WALL TYPES

(e.g. timberframe and hollow concrete)

SEEK SPECIALIST ADVICE.

INSTALLATION

1. 

ENSURE THAT FIXING KIT HAS BEEN

LOCATED BEFORE DISPOSING OF
PACKAGING.

Remove the front panel by removing the

three screws along its bottom edge. With

hands positioned on each side of the panel,

lift upwards to unhook the top edge whilst

pressing down on the top panel with your

thumbs.  The panel can now be lifted clear

and set to one side.

Remove the packing pieces from the slots

on the inner front (3 on the FXL18N and 4

on the FXL24N).

2. 

Remove the inner front panel by

unscrewing the screws along its top and

sides.  As the front insulation is attached

care must be taken when lifting this panel

from the heater and placing it to one side.

Remove the three inner guards by

removing the screws along their bottom

edges and sliding the guards up and off

the base tray. 

Please note the location of

each guard.

3. 

CONNECTION OF THE MAINS CABLE

- Connect the restricted (E7) supply to the

terminal block, marked “Storage Circuit”,

having first passed the cable through a front

cable clamp in the base. Connect the

unrestricted (Peak) supply to the terminal

block, marked “Fan/Boost Circuit”, having

passed this cable through another cable

clamp in the base.

At this point, if desired, an external fan/boost

timer may be fitted to the heater by passing

the two wires from the timer through the

remaining cable clamp, and connecting

them across the terminal block, marked

“Timer”, having already removed the link

fitted across this block at the factory.

Connect the EARTH lead from both

supplies to the terminal marked with the

symbol

IMPORTANT

 

DURING

 

NORMAL

 

OPERATION

 

ENSURE

BOTH

 

SUPPLIES

 

ARE

 

SWITCHED

 

ON

 

AT

 

THE

 

WALL

.

Содержание FXL18N

Страница 1: ... taken to ensure that prolonged skin contact with the heater does not occur Ê WHERE YOUNG CHILDREN INFIRM PERSONS OR THE AGED ARE PRESENT THIS APPLIANCE MUST BE ADEQUATELY GUARDED Contact your installer or the manufacturer for further advice Ê This appliance is very heavy and must be securely fixed to a wall DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING E...

Страница 2: ...ts bottom edge With hands positioned on each side of the panel lift upwards to unhook the top edge whilst pressing down on the top panel with your thumbs The panel can now be lifted clear and set to one side Remove the packing pieces from the slots on the inner front 3 on the FXL18N and 4 on the FXL24N 2 Remove the inner front panel by unscrewing the screws along its top and sides As the front ins...

Страница 3: ... THE FOLLOWING MUST BE APPLIED WHENFIXINGTHEHEATERTOTHEWALL BRACKET i If no skirting board is present secure the heater through the wall bracket slots closest to the wall ii If 100mm 4 in skirting is present secure the heater through the outer slots iii If skirting taller that 150mm 6in is present this must be reduced to 150mm 6 in over the entire width of the heater plus 25mm 1 in at each end Do ...

Страница 4: ...omer Help Line 0870 7270 101 Product Sales 0870 7270 103 Head Office 0870 0777 117 e mail customer services glendimplex com 86926 Issue 1 June 2006 BOOST OPTION Boost selection is controlled by a two position illuminated rocker switch The boost option is only available when the fan is in operation When the Boost is switched ON the direct acting element will be automatically activated in 2 stages t...

Отзывы: