background image

FXL(N)

 

FAN STORAGE HEATER RANGE

MODELS: FXL18N - 2.6kW / 18kWh STORAGE & 1.5kW BOOST

FXL24N - 3.4kW / 24kWh STORAGE & 1.5kW BOOST

INSTALLATION 

 

AND 

 

OPERATING

INSTRUCTIONS

IMPORTANT

PLEASE READ THIS LEAFLET CAREFULLY AND

RETAIN FOR FURTHER USE.  NOTE ALSO THE

INFORMATION GIVEN ON THE HEATER

Ê

The Installation must be carried out by trained personnel.

Ê

A means for disconnection must be incorporated in the fixed wiring by a double pole switch with a
contact separation of a minimum of 3mm and in accordance with the current IEE Wiring Regulations.

Ê

The heater must not be installed immediately below a fixed socket outlet.

Ê

The heater is not suitable for connection to a 30A ring circuit.

Ê

Do not position the heater under windows where curtains can contact the heater casing.

Ê

WARNING - THE SURFACES ON THIS HEATER CAN BE HOT.

Ê

This heater meets EN60335 safety requirements.  However, any heater type becomes hot in normal
operation.  Care must be taken to ensure that prolonged skin contact with the heater does not occur.

Ê

WHERE YOUNG CHILDREN, INFIRM PERSONS, OR THE AGED ARE PRESENT THIS APPLIANCE
MUST BE ADEQUATELY GUARDED. Contact your installer or the manufacturer for further advice.

Ê

This appliance is very heavy and must be securely fixed to a wall.  DO NOT UNDER ANY
CIRCUMSTANCES ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING
EXPERT ADVICE.

Ê

To maintain stability, it is essential that the heater is placed on a level surface.

Ê

This heater must be installed where it is impossible for switches and other controls to be touched by a
person using a bath or shower.

Ê

IMPORTANT - Due to the newness of materials the heater will produce a slight smell for the first few
days of operation.  ROOMS MUST BE WELL VENTILATED AND YOUNG CHILDREN, CAGED BIRDS,
OR PERSONS WITH RESPIRATORY COMPLAINTS MUST NOT REMAIN IN CLOSE PROXIMITY
TO THE HEATER DURING THE FIRST 48 HOURS OF THE COMMISSIONING PERIOD.

Ê

IF, DURING ANY REASSEMBLY OF THE HEATER, A PART OF THE THERMAL INSULATION
SHOWS DAMAGE OR DETERIORATION WHICH MAY IMPAIR SAFETY, IT SHOULD BE REPLACED
BY AN IDENTICAL PART.

Содержание FXL18N

Страница 1: ... taken to ensure that prolonged skin contact with the heater does not occur Ê WHERE YOUNG CHILDREN INFIRM PERSONS OR THE AGED ARE PRESENT THIS APPLIANCE MUST BE ADEQUATELY GUARDED Contact your installer or the manufacturer for further advice Ê This appliance is very heavy and must be securely fixed to a wall DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING E...

Страница 2: ...ts bottom edge With hands positioned on each side of the panel lift upwards to unhook the top edge whilst pressing down on the top panel with your thumbs The panel can now be lifted clear and set to one side Remove the packing pieces from the slots on the inner front 3 on the FXL18N and 4 on the FXL24N 2 Remove the inner front panel by unscrewing the screws along its top and sides As the front ins...

Страница 3: ... THE FOLLOWING MUST BE APPLIED WHENFIXINGTHEHEATERTOTHEWALL BRACKET i If no skirting board is present secure the heater through the wall bracket slots closest to the wall ii If 100mm 4 in skirting is present secure the heater through the outer slots iii If skirting taller that 150mm 6in is present this must be reduced to 150mm 6 in over the entire width of the heater plus 25mm 1 in at each end Do ...

Страница 4: ...omer Help Line 0870 7270 101 Product Sales 0870 7270 103 Head Office 0870 0777 117 e mail customer services glendimplex com 86926 Issue 1 June 2006 BOOST OPTION Boost selection is controlled by a two position illuminated rocker switch The boost option is only available when the fan is in operation When the Boost is switched ON the direct acting element will be automatically activated in 2 stages t...

Отзывы: