background image

Installation and Operating Instructions

 

Downflow Fan Heater 

 

 

 

 

 

 

 

 

 

 

            08/30041/3       Issue 3

 

Model  FX 20VL   

 

 

 

 

 

 

 

 

 

 

(IP22)   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 

 
Dimensions 

(millimetres) 

 
 

Model(s) Specification 

 

FX 20VL

 

(Low Level) 1/2kw + Adjustable Thermostat (external by installer) 

 
 
 
 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

 
 

General 

 
 

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND 
RETAINED FOR FUTURE REFERENCE

 
 

The heater has a loading of 2KW. It is designed for permanent wall 
mounting and is suitable for operation on A.C. electricity supply having the 
same voltage as shown on the rating label. 

 

The heater is fitted with an internally mounted selector switch which on 
installation of the heater allows a choice of 1kW or 2kW output to suit the 
dimensions of the room to be heated. 

 

In rooms of less than 9 – 11 cubic m. (350 - 400 cubic ft.) 1kW output 
should be selected, otherwise nuisance tripping of the thermal overload 
cut-out may occur. 

 
 

NOTE : THE SWITCH HAS BEEN FACTORY SET FOR 2kW 
OPERATION. 

 
 

 

 

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 Fig. 

1

 

 

 

 

 

SUPPLY CABLE IS NOT SUPPLIED WITH THIS APPLIANCE AND IT 
SHOULD THEREFORE BE INSTALLED BY A COMPETENT 
ELECTRICIAN IN ACCORDANCE WITH THE IEE REGULATIONS. 

 
 

The Controls

 

 
The

 cut-out

 is a safety device which switches off the heater and fan if for 

any reason the appliance overheats. (see ‘Safety’) 
 
The

 thermal fuse link

 is provided as an added safety feature, and 

operates to open circuit if there is abnormal overheating within the 
appliance. The operation of these safety devices is described under 
‘Safety’ 
 
This model is also fitted with an 

adjustable thermostat

 which can be 

adjusted by user. This has the following settings : 0, 

*

 (frost protection), 1, 

2, 3, 4, 5 (max). The thermostat should be set to 5 (max). Once the 
required room temperature is reached, it can be turned back until a click 
(switch off) can be heard, which will give you a constant room temperature 
with the thermostat switching on and off automatically. This gives you an 
approximate room temperature range of 7°C - 32°C depending on room 
size. Frost protection : When the temperature falls below + 5 … +8°C, the 
appliance switches on automatically.  
Note – On this model the thermostat works independent from the selected 
output. 
 
To reset the selector switch first remove the top cover, then adjust 
thermostat to required setting, or reset selector switch to 1kw or 2kw as 
required, then refit top cover. 
 

 
 

Safety 

 

Cut-Out 

For your safety, this appliance is fitted with a thermal cut-out. In the event 
that the product overheats, the cut-out switches the heater off 
automatically. 
To bring the heater back into operation, remove the cause of overheating, 
then turn off the electrical supply to the heater for a few minutes. 
When the heater has cooled sufficiently reconnect and switch on the 
heater. 

 
 

Fuse Link 

A thermal fuse link is provided as an added safety feature. If the fuse link 
operates and opens circuit it is the result of abnormal overheating within 
the appliance, and servicing of the appliance by a competent service 
engineer will be required in order to ensure the future safe operation of the 
heater. Dimplex Customer Services should be contacted, who will arrange 
the replacement of any faulty parts and the fitting of a new fuse link.

  

 
 

 

IMPORTANT SAFETY ADVICE

 

 

WARNING  - DO NOT USE THIS HEATER IN THE IMMEDIATE  
SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING POOL. 

 

THIS APPLIANCE CARRIES A WARNING ‘DO NOT COVER’ TO 
ALERT THE USER TO THE RISK OF OVERHEATING THAT EXISTS 
IF THE APPLIANCE IS ACCIDENTALLY COVERED. 

 

DO NOT COVER THE APPLIANCE  or place material or garments 
on it, or obstruct the air circulation around this appliance, for 
example with curtains or furniture, as this could cause 
overheating and a fire risk. 

 

DO NOT PLACE AEROSOLS OR OTHER CONTAINERS 
SUSCEPTIBLE TO HEAT IN THE DIRECT AIRFLOW FROM THE 
UNIT. 

 

THIS HEATER MUST NOT BE LOCATED IMMEDIATELY BELOW A 
FIXED SOCKET OUTLET. 

 

WARNING – DISCONNECT THE HEATER FROM THE ELECTRICITY 
SUPPLY BEFORE UNDERTAKING SERVICE OR REPAIR. 

 

WARNING – If the appliance is fitted in a bathroom, a cable outlet 
will be necessary with the supply to the unit controlled by a 
double pole switch. The switch if inside the bathroom should be 
pull cord operated and if outside should be adjacent to the 
entrance door. The appliance must be mounted so that no part of 
it can be touched by any person using bath or shower. 

 

THIS HEATER MUST NOT BE OPERATED WITHOUT THE COVER 
CORRECTLY IN POSITION. 

Отзывы: