5. Presetting

 

 

Take care! The settings must be carried out  by a 

competent electrician. Ensure that the appliance is 
disconnected from the mains. 

5.1 Selecting the heating capacity 

The wall mounted fan heater is provided with an internal 

selector switch with which the output can be set during 

installation to 1 kW or 2 kW corresponding to the size of the 

room to be heated. 
In rooms of less than 11 m3 in volume, the 1 kW output 

should be selected as otherwise nuisance tripping of the 

thermal cut-out may occur.  
In case of selecting the 2 kW position, the thermostat is in 

operation and will switch automatically to 1 kW when the 

preselected temperature is achieved. 
Note: the heater is preset to 2 kW.  

5.2 Selecting the temperature 

Note: the thermostat will only function when 2KW is 
selected. 
The heater is fitted with an adjustable thermostat, which has 
three different settings : 1. - Low, 2. - Medium, 3 - High. 
This gives you an approximate room temperature range of 
18°C - 32°C depending on room size. The temperature 
switches to half heat when the room warms up. Full heat will 
be switched on automatically when the room temperature 
falls. 
The thermostat has been factory set on ‘2’ (Medium). 

 
6. Heater operation

 

The pull cord operates the ON/OFF switch. The pilot lamp 
will illuminate when the heater is switched on. 

 

 

7. Faults  

If the heater is not heating, check whether the heater is 
switched on (pilot lamp must illuminate). Check that it is 
switched on at the distribution board and that the fuse is 
intact.  
Further directions are explained in section "9. Thermal 
safety cut-out". 
In the event of malfunctions in your heater, please contact 
your local electrician or the nearest customer service point.  
The E-Number and the FD code are required before 
servicing can be carried out. You will find them on the rating 
plate. 
 

8. Cleaning the appliance 

Switch off the heater before cleaning and allow to cool.  
If dust accumulates, the heater should be cleaned from the 
outside using a vacuum cleaner. 
The outside can be cleaned by wiping it over with a soft 
damp cloth and then dried. Do not use abrasive cleaning 
powders or furniture polish, as this can damage the surface 
finish.  
 

9. Thermal safety cut-out 

For your safety the heater is fitted with a thermal cut-out.  
If the air circulation is restricted (e.g. hanging something 
over or blocking the grille) the heater switches off 
automatically. In order to bring the heater back into 
operation remove the cause of the overheating. Switch off 
the heater for a few minutes by pulling the cord and allow to 
cool down after which normal operation may be resumed. 
In addition the appliance is fitted with a thermal fuse link.  

If there is abnormal overheating within the appliance, it 

operates and opens the circuit. 

 
10. Guarantee  

The guarantee terms issued by our representatives in the 
country of purchase are applicable for this appliance. The 
dealer from whom the appliance was purchased will provide 
details at any time on request. Presentation of a receipt is 
essential for the implementation of the guarantee terms.  