SPECIFICATIONS 

 

                          MODEL 

SPECIFICATION                 

FTE10 

FTE16 

FTE20 

POWER SUPPLY 

220-240V~50Hz 

POWER INPUT 

250W 

410W 

480W 

RUNNING CURRENT 

1.2A 

2.1A 

2.2A 

WEIGHT 

11.1Kg 

13.3Kg 

13.7Kg 

MOISTURE REMOVAL     

(@ 30

& RH 80%

 

10 litre/day   

16 litre/day 

20 litre/day 

DIMEMSIONS 

(WxDxH)mm 

W:365 x D:220 x H:500 

APPLICABLE 

TEMPERATURE 

5

 - 35

 

WATER TANK CAPACITY 

2.3L 

 

(CE) N 842/2006: 

R134A is a kind of fluorinated greenhouse gas covered by 

the Kyoto Protocol. 

Its total global warming potential (GWP) is 1300 

 

 

 

 

 

Recycling:

 For electrical products sold within the European 

Community.    At the end of the electrical products useful life it 
should not be disposed of with household waste.   
Please recycle where facilities exist. 
Check with your Local Authority or retailer for recycling advice in 
your country. 

Содержание FTE10

Страница 1: ...____________ Products comply with the European Safety Standard EN60335 2 40 and the relevant parts of the European Standards for Electromagnetic Compatibility EMC EN55014 and EN61000 along with EN6223...

Страница 2: ......

Страница 3: ...he dehumidifier or the air inlet slots at the rear of the dehumidifier 10 To prevent spillage empty the water tank before relocating the appliance 11 Do not tip the appliance to any side as escaping w...

Страница 4: ...OPERATING INSTRUCTIONS 1 Control panel 2 Air outlet 3 Carry handle 4 Front panel 5 Air inlet 6 Water outlet tube continuous use 7 Water tank...

Страница 5: ...switch fully anticlockwise to the OFF position and the power supply is cut off and the unit stops operating 2 If the dehumidifier is not in use for a long time please disconnect the power cord plug f...

Страница 6: ...s 6 Other than on the case of note 2 above where the dehumidifier does not start the operational light does not illuminate or the dehumidifier intermittently stops for unknown reasons please check the...

Страница 7: ...fit the tank to reset the light CONTINUOUS DRAINAGE If you want to use this function please pull out the water tank and plug a 9mm internal diameter water pipe onto the Water out tube See Fig 02 Repla...

Страница 8: ...For a better dehumidifying effect the areas to the front rear and above the unit should be clear and free from any obstacles which will block the air flow of the unit Do not block any air inlet or out...

Страница 9: ...PLICABLE TEMPERATURE 5 35 WATER TANK CAPACITY 2 3L CE N 842 2006 R134A is a kind of fluorinated greenhouse gas covered by the Kyoto Protocol Its total global warming potential GWP is 1300 Recycling Fo...

Страница 10: ......

Страница 11: ...purchase any spares Please do not return any faulty product to us in the first instance as this may result in loss or damage and delay in providing you with a satisfactory service Please retain your r...

Страница 12: ......

Отзывы: