near right side.  Feed service leads through and secure 

end of cable to the connector.
Remove the rear knockout on top of heater wall box near 

4. 

right side and insert bushing (provided).  Feed service 

wires through bushing.  Secure wall box to surface box 

with four sheet metal screws (provided with the surface 

box).  Screws are inserted through the inside holes on 

the flanges.
Proceed with steps 7 through 11 inclusive in recessed 

5. 

heater installation instructions.

Wiring

Two conductor non-metallic sheath cable with ground wire is 

recommended for recessed installation of these heaters while 

two conductor, metallic sheath cable (BX) is recommended 

for surface installations.  Use number 12 gauge wire for all 

models.  Each heater should be on an individual, properly 

fused circuit.

 WARNINg:  

Wiring procedures and connections should 

be in accordance with the National Electric code (NEC) and 

local codes.

When installing optional wall thermostat, unit mounted 

1. 

 Operation

 

maintenance

These heaters are operated by an on/off switch and also a 

temperature control with a knob.

Turn the switch ON.  Remember there is a fan delay.

1. 

Set thermostat by turning the knob to desired room 

2. 

comfort level (clockwise to increase heat output).  Once 

you have determined the proper setting to provide the 

heat level you prefer, you need not touch the knob again.
Turn the switch OFF to turn off heater.  To reuse, simply 

3. 

turn the switch ON - the temperature level you wish has 

been previously set.

!

  NOTE:

  This heater is equipped with a fan delay switch 

which delays the fan operation until the heating grid has 

heated sufficiently to assure the circulation of only warm air.  

This same switch permits the fan to operate after power to 

the grid has been shut off by thermostat action, thus utilizing 

all the heat remaining in the grid.
When the heater is shut down by turning the switch OFF, 

power to both fan motor and element is diconnected and the 

fan motor will not continue to operate.

 WARNINg:

Should the OVERTEMP light come on, 

disconnect power to the heater, turn the switch OFF or 

turn down the thermostat fully counterclockwise and call 

a licenced electrician.  DO NOT USE HEATER UNTIL 

PROBLEM IS DETERMINED AND FIXED.

Tamper proof models

The ON/OFF switch and the temperature regulating 

thermostat are recessed so that the continuous grille front 

panel can be installed concealing both controls.  The 

thermostat is operated by removing the front panel.  The 

ON/OFF switch can be operated by inserting a slender non 

metallic rod between grill louvers and turning the switch ON 

or OFF.

This heater requires no maintenance other than a cleaning at least 

once a year.

  CAuTION:

  Before removing heater parts, open branch 

service switch or remove fuses.  These are located at the 

distribution panel.
To clean, remove frame, grille and heater assembly.  Remove 

any dust and dirt from wall box and heater assembly with a 

soft cloth or brush, then re-install heater assembly making 

sure that the fan turns freely and service leads are away from 

fan area.  The frame and grille may be washed with a mild 

detergent, however make sure they are thoroughly rinsed 

and dried before re-installation. 

Figure 3

thermostat must be set at it’s highest setting.
All external control equipment (shown with dashed lines) 

2. 

furnished by customer.  Control wiring must be suitable 

for 600V.
Heater branch circuits shall have a carrying capacity of 

3. 

no less than 125% of maximum load served.

HEATER WALL BOX

SHEET METAL 

SCREW

GROUNDING 

SCREW

REMOVE THIS 

KNOCKOUT

SERVICE CABLE

25” SERVICE 

LEADS

Figure 2: Surface

SURFACE 

WALL BOX