background image

Setting the Timer Programmes

There are four program segments available, 

P1

P2

P3 

and 

P4

. For each segment it is possible to set a desired 

‘On’ time, ‘Off’ time, Heat mode and set temperature. It is 

not necessary to set all four segments if not required. The 

default setting is for all segments to be Off. To turn off a 

pre-programmed segment it is necessary to set both the ‘On’ 

time and the ‘Off’ time to 00:00. In order to set up a time/

temperature profile the following steps must be completed: 

1. To activate the programming screen press the ‘ ’ key. 

The program settings screen for 

P1

 will be displayed and 

the time will be flashing. This flashing time is the ‘On’ time 

for 

P1

 and can be adjusted using arrow keys. Once the 

desired ‘On’ time has been set press the 

ENTER

 key to 

confirm the time.
2. Select a heat setting using the arrow keys and confirm 

the selection using the 

ENTER

 key.

3. Set the desired temperature using the arrow keys and 

confirm the setting using the 

ENTER

 key.

4. The ‘Off’ time must then be set by using the arrow keys, 

it is necessary to then press the 

ENTER

 key to confirm the 

‘Off’ time setting.
5. The setup screen will then revert to the 

P1

 ‘On’ time set 

up screen, at this point it is possible move to the 

P2

 segment 

by pressing the ‘ ’ key.
6. If required 

P2

P3 

and 

P4

 segment can be set up using 

steps 1-4 above.
7. If it is not required to set up 

P2

P3

 and 

P4

 segment at this 

stage, continue to press the ‘ ’ key until the heater reverts 

to the previous operational mode. Alternatively if no keys 

are pressed the programming mode will time out and revert 

to the previous operational mode.

Note:

 it is possible to overlap the on times of program blocks. 

In the event of an overlap the program with the highest 

temperature set point will take priority during the overlap 

period. Once the overlap period has expired the product will 

revert to the later program settings. If an overlap is present 

the display will indicate the current operational program and 

the off time of the final overlapping program.   

Remote Bluetooth Operation

The appliance can be controlled remotely using a 

smartphone or similar device. To facilitate this remote 

operation it is necessary to first download the Dimplex 

 

app. The app is available on both android and IOS devices 

and is available free from the Apple or Android App store. 

The App is compatible with Android version 4.3 and above 

and IOS version 5 and above. 
Once the App has been downloaded it is necessary to pair 

the appliance with the smartphone to complete the remote 

setup. Please follow the steps shown below:

1. Launch the Dimplex 

 app on the smartphone or 

similar device.
2. To initiate pairing mode on the appliance press and hold 

the ‘

’ button for two seconds. The LCD screen will go blank 

with the exception of the Bluetooth 

 logo flashing in the 

bottom right hand corner, See 

Fig.10.

This indicates that 

the device is advertising to be paired with the 

 app.

3. On the smart phone the appliance should now be visible 

on the pairing screen, this will be a unique 6 digit code but 

will always start with EC, for example ‘ECBC17’. Select this 

device and press connect to initiate pairing.
4. Once the paring process is complete the app can be used 

to control the appliance. 

5. Once paired successfully the Bluetooth logo will stop 

flashing and the Bluetooth neon will be illuminated.

Содержание EvoRad Series

Страница 1: ...mpatibility EMC EN55014 1 EN55014 2 EN61000 3 2 and EN61000 3 3 which cover the essential requirements of EMC Directive 2014 30 EU and the LVD Directive 2014 35 EU THESE INSTRUCTIONS SHOULD BE READ CA...

Страница 2: ...tus Ac ve segment Flashing Model Identifier s EvoRad2BT EvoRad2BTA Heat output Nominal heat output Pnom 2 0 2 0 kW Minimum heat output indicative Pmin 0 8 0 8 kW Maximum continuous heat output Pmax c...

Страница 3: ...vice agent or a similarly qualified person in order to avoid a hazard DO NOT use the heater where gas petrol paint or other inflammable goods are used or stored Warning The heater complies with string...

Страница 4: ...ture approaches the desired level This mode optimises energy use by calculating the most efficient and effective way to achieve the desired temperature setting The desired room temperature can be adju...

Страница 5: ...ER key The default heat setting is ECO mode and the set temperature is 25 C The set temperature can be adjusted if desired see Setting the Desired temperature When the boost mode is active the LCD dis...

Страница 6: ...to the previous operational mode Note it is possible to overlap the on times of program blocks In the event of an overlap the program with the highest temperature set point will take priority during t...

Страница 7: ...tically until the reason for overheating is removed Storage If the heater is not required for long periods for example during the summer it should be stored in a dry place and preferably covered to pr...

Страница 8: ...es outside Dimplex s control caused by use of your Dimplex product for anything other than normal domestic household purposes in the country where it was purchased caused by any misuse abuse or neglig...

Отзывы: