Always unplug the unit from the mains before carrying out any maintenance or cleaning 
of the unit.

CLEANING THE BODY

Use a soft damp cloth to wipe the unit clean.
Don’t ever use volatile chemicals, gasoline, detergents, chemically treated clothes,  
or other cleansing solutions. These all could possibly damage the enclosure. 

CLEANING THE FILTERS

This dehumidifier is equipped with 2 filters.
The plastic dust filter is washable and should be cleaned approximately every 2 weeks 
when in use (see instruction below).
The active carbon filter is not washable. The active carbon filter should be removed 
regularly and cleaned with a dry cloth.  It should be placed in sunlight (on window sill)  
for a few hours every 3- 6 months to help re-charge the active carbon properties.  

WASHING THE PLASTIC DUST FILTER

•  Remove the anti-dust filter and separate the active carbon filter (not washable) 

and set it aside carefully. 

•  Use a vacuum cleaner or tap the plastic air filter lightly for easy cleaning. If the 

filter is particularly dirty, use warm water with a small amount of medium strength 
detergent to rinse the filter.  

•  Allow it to dry naturally and make sure the filter is completely dry before replacing.
•  Do not expose the filter to sunlight.

STORAGE

If not using the unit for an extended period of time. Please:
•  Turn the unit off, unplug and take care of the mains lead & plug.
•  Completely empty the water tank and clean it thoroughly and wipe it dry.
•  Cover the unit and store it upright in a location where it will not receive direct 

sunlight. NB- Prolonged exposure to direct sunlight will discolour the enclosure. 

Maintenance

Anti-Dust  
Filter

Active Carbon
Filter 

Air Inlet

12

Содержание everdri 20 E

Страница 1: ...ls 20 E and EL These products fully comply with all current European Safety Standard requirements for Dehumidifiers and are fully compliant with the Low Voltage Directive 2014 35 EU the EMC Directive...

Страница 2: ...ant caused by electric heaters stoves or other sources of ignition When defrosting and cleaning the appliance do not use any tools other than those recommended by the manufacturing company The applian...

Страница 3: ...damage Never operate the appliance if a cable or connector has been damaged after appliance malfunction or if the appliance was dropped or is otherwise damaged If the mains lead is damaged it must on...

Страница 4: ...flammable or explosive substances or fuels Never use any paint cleaning sprays anti insect sprays or similar near the unit this could damage or deform the plastic cause electrical damage or be a fire...

Страница 5: ...xtension lead may become overload Where there is risk of fire or close to a naked flame Where the power cable may be damaged On a slope or uneven surface Where it may be damaged by chemicals If there...

Страница 6: ...2MPa Maximum Pressure of Coil MPa 9 6MPa Refrigerant R290 GWP 3 Refrigerant Charge kg 0 070kg CO2 Equivalent tonnes 0 00021 tonnes Contains fluorinated greenhouse gases Hermetically sealed system Cont...

Страница 7: ...t will try and target 40 relative humidity ambient humidity which is for drier conditions Nearer 70 setting the product will try and target 70 relative humidity e g more humid moist conditions Unless...

Страница 8: ...d on a level surface and that there is a minimum of 50 cm 20 of space on either side of the unit to allow for efficient airflow This dehumidifier is fitted with castors for extra mobility if you move...

Страница 9: ...he unit running when the light is red to tackle severe damp conditions then do so Control Panel 1 Humidity setting button 2 Working mode indicator continuous working humidity 40 50 60 70 3 Humidity Te...

Страница 10: ...ON OFF button you can PRE SET the time for the product to switch on later For example if you press the timer to 2 the unit will switch on automatically after 2 hours 8 Optional functions PCO Photo Ca...

Страница 11: ...ated at very high humidity levels the water tank will require more frequent emptying In this situation it may be more convenient to set the unit up for continuous drainage this can be done as follows...

Страница 12: ...arge the active carbon properties WASHING THE PLASTIC DUST FILTER Remove the anti dust filter and separate the active carbon filter not washable and set it aside carefully Use a vacuum cleaner or tap...

Страница 13: ...not damaged ERROR FAULT CODE MESSAGES ON DISPLAY E1 or E2 Flashing Sensor malfunction Please stop using the product and Contact Customer Service E3 Flashing Connection malfunction Please stop using th...