background image

 WARNING: 

This heater must be properly installed before it 

is used.

CONTROLS

•  Fan Delay -

 The heater is equipped with a fan delay con-

trol.  There will be a short delay to enable the heating ele-

ments to warm up before the fan turns on.  The fan will 

also remain on for a few moments after the elements are 

de-energized.

•  Automatic High Limit 

- Each heater is equipped with au-

tomatic reset thermal cutouts.  Should these safety switch-

es operate, they will automatically reset once the element 

reaches a safe operation temperature, however, the cause 

of the high limit condition should be determined and  cor-

rected to sure satisfactory operation.

OPTIONAL CONTROLS

•  Integral thermostats 

- All units are available with a built-in 

snap-action  thermostat.   The  sensing  element  is  located 

in  the  return  air  stream  to  provide  accurate  temperature 

control.  The thermostat has a range of 40°F (5°C) (low) to 

100°F (38°C) (high).  It can be manually operated or ren-

dered tamper-proof as desired.  This control can be field-

mounted or factory mounted.

•  Remote Line Voltage Thermostat

 - All units can be con-

nected to a line-voltage remote thermostat.  A special con-

trol terminal block is provided in all units to facilitate easy 

connection of the remote thermostat control wiring.

•  Remote Low Voltage Thermostat with Relay

 - A low volt-

age transformer/relay can be field or factory installed with 

the unit for remote low voltage thermostatic control.  The 

special  control  terminal  block  is  utilized  for  this  optional 

control feature.

•  Fan-Only Switch - 

An optional fan-only switch is available 

for integral mounting within the unit.  This switch provides 

continuous  fan-operation,  independent  of  the  built-in  or 

optional remote thermostatic control, which is effective in 

eliminating air stratification.

START UP

1.  Before the unit is energized, the discharge louvres should 

be adjusted for desired air deflection.

2.  Check to see that all controls and optional accessories are 

operation properly.

 

Maintenance

 CAUTION:  

Before removing the front cover for cleaning, 

make certain the power has been turned off at the circuit 

breaker panel.

 CAUTION: 

Allow adequate time for the element and body 

casing to cool before attempting to work on the heater.

1.  Under  normal  conditions,  the  heater  should  be  cleaned 

once a year. 

DISCONNECT ALL POWER

 before cleaning 

or servicing the heater.

2.  All motors are lubricated for extended life operation, and 

will not have to be oiled.

 

Warranty

The Manufacturer warrants the heating elements and components of the enclosed 

product  against  any  defect  in  material  or  workmanship  for  a  period  of  one  year 

from the date of purchase.  In full satisfaction of any claims under this Warranty the 

Manufacturer will repair or replace without charge, in its factory or in the field as it 

alone may decide, any parts which in its opinion are defective.
The Manufacturer shall not be responsible for any transportation or shipping costs in 

relation to such repair or replacement except as specifically assumed by it.  Misuse 

of  this  product  or  repairs  by  persons  other  than  the  Manufacturer’s  authorized 

personnel without the Manufacturer’s written approval, will void this Warranty.
This  Warranty  is  in  lieu  of  all  other  warranties  or  conditions  whether  express  or 

implied including but not limited to those of merchantability or fitness for purpose 

and shall constitute the sole remedy of the Purchaser and the sole liability of the 

Manufacturer in respect of the sale of the product, whether in the nature of breach 

or breach of fundamental term, or of negligence or otherwise.
The  Manufacturer  shall  not  be  liable  for  any  special,  indirect  or  consequential 

damages or for any damages resulting from removal or replacement of a heater 

subject to warranty claim without the Manufacturer’s authorization.
This Warranty is transferable by the original  consumer purchaser of the product.  

Any claims under this Warranty must be submitted in writing to the Service Manager, 

Dimplex  North America  Ltd.,  1367  Industrial  Rd.,  Cambridge,  Ontario  N1R  7G8, 

Canada.

In keeping with our policy of continuous product improvement, we reserve the right to make changes without notice.

© 2014 Dimplex North America Limited

1367 Industrial Road    Cambridge ON Canada N1R 7G8
1-888-346-7539    www.dimplex.com

 Operation

Replacement Parts

Thermostat   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03005043RP

Control Knob  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02028016RP

Control Fuse  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04005103RP

Terminal Block  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4000040600RP

Grille   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30006159-SARP

15-25kW

30kW

40-50kW

Fan Blade

02000017RP

02000018RP

02000045RP

Motor

2000080200RP

2000090100RP

3024019RP

Casing

30006730-SARP

30006851-SARP

Louver

30000013-SARP

30006855-SARP

Hi Limit 

Cutout

03005039RP

03005046RP

Fan Delay 

Relay

06942602RP

03005044RP

Capacitor

00857007RP

02007005RP

N/A

Contactor

2400160300RP

2400161300RP (above 48A)

2400160200RP

Transformer

347V: 2100080022RP

480V: 2100080011RP

600V: 2100080012RP

480V: 02005869RP

600V: 03005045RP

208V 

Elements

15kW: 2200270100RP

20kW: 2200270500RP

25kW: 2200270800RP

2200271800RP

N/A

240V 

Elements

15kW: 2200270200RP

20kW: 2200270100RP

25kW: 2200270900RP

N/A

N/A

347V 

Elements

15kW: 2200271400RP

20kW: 2200271600RP

N/A

N/A

480V 

Elements

15kW: 2200270300RP

20kW: 2200270600RP

25kW: 2200271000RP

2200271200RP

40kW: 02038336RP

(9 elements/unit)

60kW: 02038338RP 

(9 elements/unit)

600V 

Elements

15kW: 2200270400RP

20kW: 2200270700RP

25kW: 2200271100RP

2200271300RP

40kW: 02038337RP

(9 elements/unit)

60kW: 02038338RP

(9 elements/unit)

*All units have 6 elements unless otherwise indicated

Отзывы: