background image

7202450001R11

Electric Unit Heaters

EUH-B Series

   WARNING: 

Wiring procedures and connections should be in ac-

cordance with the National Electric code (NEC) and local codes.

 WARNING: 

To reduce the risk of fire, do not store or use gasoline 

or other flammable vapors or liquids in the vicinity of the heater.

FOR HORIZONTAL OR VERTICAL AIRFLOW 

PERMANENT OR SUPPLEMENTARY ELECTRIC FORCED AIR 

HEATING FROM THE SAME VERSATILE UNIT

These heavy-duty heaters provide spot heating for hard to heat ar

-

eas, or they can be used as the primary source of heat for areas not 

reached by an existing heating system.
The fan and motor are carefully matched to insure quiet, trouble-free 

operation and fan blades are precision balanced before installation.

Heaters in all capacities (3, 5, 7½, 10 or 12kw) have the same di

-

mensions, and use the same mounting brackets. All components and 

controls, including thermostat, transformers, relays, and switches are 

enclosed inside the case. Wiring is simple and all heaters can oper

-

ate from a single power source.

HEATER LOCATION

Unit heaters should be located along outside walls to provide perim

-

eter air circulation. The discharge air should wipe the walls without 

blowing directly on them. (Figure 1)

• 

Small rooms

 - can be heated by one or two units. Locate the unit 

 Installation Instructions

IMPORTANT INSTRUCTIONS

When using electrical appliances, basic precautions should always 

be followed to reduce the risk of fire, electric shock and injury to per

-

son, including the following: 

1.  Read all instructions before using this heater.
2. 

A heater has hot and arcing or sparking parts inside. Do not use 

it in areas where gasoline, paint or flammable liquids are used 

or stored.

3. 

The heater is hot when in use. To avoid burns, do not let bare 

skin touch hot surfaces. The trim around the heater outlet be

-

comes hot during heater operation. Keep combustible materials, 

such as furniture, pillows, bedding, papers, clothes, etc. and cur

-

tains at least 3 ft. (0.9m) from the front of the heater.

4. 

Extreme  caution  is  necessary  when  any  heater  is  used  by  or 

near children or invalids and whenever the unit is left operating 

and unattended.

5. 

Do  not  operate  any  heater  after  it  malfunctions.  Disconnect 

power at the service panel and have the heater inspected by a 

reputable electrician before reusing.

6. 

Do not use outdoors.

7. 

To disconnect the unit, turn the controls off, and trun off power to 

heater circuit at main disconnect panel.

8. 

Do not insert or allow foreign objects to enter any ventilation or 

exhaust opening as this may cause an electric shock or fire, or 

damage to the heater.

9. 

To prevent a possible fire, do not block air intake or exhaust in 

any manner. 

10. 

Do not modify this heater. Use it only as described in this man

-

ual. Any other use not recommended by the manufacturer may 
cause fire, electric shock or injury to persons.

SAVE THESE INSTRUCTIONS

heater(s) to provide circular air movement within the space.

• 

Large rooms 

- requiring multiple unit installations. Units should 

be located so that the discharge air from one unit supports the 

discharge from another unit and provides a circular air movement.

• 

Remote thermostats 

- should be located on interior walls or 

posts away from heat sources, cold drafts, and away from heater 

discharge streams.

MOUNTING UNIT HEATER(S)

 CAUTION: 

Heater must be mounted a minimum of 10 in. (25.4cm) 

from walls and 6 ft (183 cm) above floor (8 ft (244 cm) for vertical air 

flow) with the discharge parallel to or away from wall. 

• 

MOUNTING BRACKET 

- The  heater  is  shipped  with  a  mount

-

ing bracket packed separately in the carton. Secure the bracket 

to  threaded  attachment  points  on  the  sides  of  the  heater  with 

two bolts (provided). Select desired angle of tilt (Horizontal, 15, 

30, 45, 60, 75, or Vertical), remove corresponding knockouts on 

sides of the heater, then screw the remaining two bolts into the 

threaded holes in the bracket so that the bolts pass through the 

knockout holes. The unit is now ready for hanging.

• 

CEILING MOUNTING

 - Fasten the heater securely to the ceiling 

using the center hole in the bracket or the two holes on either side 

of the center hole. The Unit mounting bracket may be attached 

directly to the ceiling.

• 

WALL MOUNTING

 - The heater may also be mounted to a wall 

with accessory wall bracket, Part # EUHWB. The wall bracket at

-

taches to the center hole of the unit mounting bracket.

WIRING

1. 

Connect the heater only to the voltage and frequency specified 

on the nameplate.

2. 

All  wiring  to  be  in  accordance  with  local  and  national  electric 

codes.

3. 

Remove two screws securing the access door (See Figure 2) and 

swing the door down to expose the wiring and control compart

-

ment.

4. 

Three knockouts are provided at the back of the heater for power 

and control wiring. (See Figure 2)

5.  Rough-in branch circuit wiring to the heater using wire rated for 

167°F (75°C). Wire heater supply according to diagram attached 

to the access door.

SMALL ROOM

LARGE ROOM

EXPOSED OUTSIDE WALL

EXPOSED OUTSIDE 

W

ALL

EXPOSED OUTSIDE WALL

Figure 1