Installation

The Fixing Kit should contain: 1 Drilling Template, 3 Screws, 3 

Rawlplugs and 1 Mounting Bracket.

Wall Mounted Operation  

(see 

Fig. 2

)

Suggested Fixings

SOLID BRICK/BLOCK:  

No. 8 Rawlplug inserts, 6mm drill bit.

PLASTERBOARD: 

 If possible locate studding and use No. 8 

woodscrews directly into the wood, otherwise M5 rawlplug intersets 

are suitable.

NOTE: FOR OTHER WALL TYPES 

(e.g. Timber frame and hollow 

concrete) 

SEEK SPECIALIST ADVICE.

1.

  Select the position for the heater ensuring there is 

clearance  from  any  furniture  and  fittings  of  at  least 

150mm above the heater, 50mm below, 25mm each 

side and 300mm from the front panel. Curtains must 

not be closer than 150mm from the top and/or sides of 

the heater. 

2.  Position the drilling template provided on the wall ensuring 

it is level.  Mark the position of the relevant holes on the 
wall  at the edge of template.  Before drilling check that the 
distance between the hole centres is correct, 340mm for 
400W Models and 540mm for 800W models (see 

Fig.  2

).

Fig. 2

Positioning the Heater

Select the position for the heater ensuring there is clearance 

from any furniture and fittings of at least 150mm above the 

heater, 50mm below (wall mounted), 25mm each side and 

300mm from the front panel. Curtains must not be closer than 

150mm from the top and/or sides of the heater. 

Free Standing Operation 

(see 

Fig. 1

)

NEVER USE THE HEATER FREE STANDING WITHOUT THE 

FEET FITTED 

(FEET ARE PACKED SEPARATELY IN CARTON).

1. Lay the heater on its front.
2. Remove the two star head screws from the base of the 

heater using a x-head screwdriver.

3. Place feet over base of heater, align holes and engage hook 

on foot into the recess on the back of the heater - see 

Fig. 

1

.   

4. Replace the screws but do not overtighten.

Fig. 1

Rear View

3.  Drill the wall at the three marked positions and fit the wall 

plugs.  

  Ensure template has been removed.

4.  Fix two No. 8 screws to the top two holes leaving 3mm of 

the screw exposed.  Hang the heater on the screws.

5.  Fit the bottom bracket, found in the fixing kit, in the slot at 

the base of the heater and screw the bracket to the wall.

           Test that the heater is now securely fixed to the wall.

130mm

340mm - 400W
540mm - 800W

95mm

150mm

50mm

420mm

25mm

25mm

130mm

Drilling Holes

Bracket

Electrical Connection

WARNING THIS APPLIANCE MUST BE EARTHED

If the socket outlets in your home are not of the 13 amp BS1363 

type they will not accept the plug connected to this heater, 

therefore cut off the plug.  When cut off this plug can constitute 

a shock hazard if inserted into a socket outlet.  It must therefore 

be disposed of safely.
Before wiring the appropriate plug please note that the wires in this 

mains lead are coloured in accordance with the following code.

GREEN/YELLOW: 

  

EARTH

BLUE:   NEUTRAL

BROWN: 

  LIVE

Connect the 

Green/Yellow

 wire to the terminal marked 

E

 or the 

earth symbol   or coloured 

Green

 or 

Green/Yellow

.

Connect the 

Brown

 wire to the terminal marked 

L

 or coloured 

Red

.

Connect the 

Blue

 wire to the terminal marked 

N

 or coloured 

Black

.

DO NOT 

connect the 

Brown

 (

Live

) or the 

Blue

 (

Neutral

) wires 

to the 

Earth

 terminal of your 13 amp plug.  If the terminals of the 

plug are unmarked or you are in any doubt, consult a qualified 

electrician.

CAUTION: 

If you use this heater in conjunction with a thermal 

control, programme controller, timer or any other device which 

switches the heater on automatically observe all safety warnings 

at all times.

Please Note: Although this heater is manufactured to 

comply with the relevant safety standards, certain types 

of carpets could become discoloured by the temperatures 

under a portable heater. If you are concerned about this, 

we recommend that you contact the carpet manufacturer 

for guidance. Alternatively, either stand the heater on a 

suitable base to shield the carpet or wall mount it.

Содержание DXLWP800TI B

Страница 1: ...s millimetres Models Specification DXLWP400 400W Neon Heat Switch DXLWP400TI 400W Neon Heat Switch 24 Hour Timer DXLWP800 800W Neon Heat Switch DXLWP800TI N 800W Neon Heat Switch 24 Hour Timer DXLWP800TI B 800W ON OFF 2 Switches 24 Hour Timer ARLWP800TI 800W 2 Neon Heat Switches 24 Hour Timer THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE 600 mm 400W 800 mm 800W 500 ...

Страница 2: ...itions and fit the wall plugs Ensure template has been removed 4 Fix two No 8 screws to the top two holes leaving 3mm of the screw exposed Hang the heater on the screws 5 Fit the bottom bracket found in the fixing kit in the slot at the base of the heater and screw the bracket to the wall Test that the heater is now securely fixed to the wall 130mm 340mm 400W 540mm 800W 95mm 150mm 50mm 420mm 25mm ...

Страница 3: ... warnings when operating the heater on auto setting unattended or attended If the mains supply to the heater is interrupted the timer clock will stop until power is restored reset the time of day to ensure correct ON and OFF times Operation IMPORTANT OBJECTS OR CLOTHING MUST NOT BE PLACED ON THIS HEATER Before using the heater ensure that all warnings and instructions have been read carefully OPER...

Страница 4: ...quire after sales service you should contact our customer services help desk on 0844 879 3588 It would assist us if you can quote the model number series date of purchase and nature of the fault at the time of your call The customer services help desk will also be able to advise you should you need to purchase any spares Please do not return a faulty product to us in the first instance as this may...

Отзывы: