5.  Other than on the case of note 2 above, where the dehumidifier does not 

start, the operational light does not illuminate or the dehumidifier 
intermittently stops for unknown reasons, please check the plug and power 
supply for poor connection. If the plug and power supply are in good 
condition, wait for 10 minutes and restart the unit (it can take about 10 
minutes for the unit to reset). If the unit still does not start after 10 minutes, 
please contact your retailer or the manufacturer for repair.

 

6.  When the dehumidifier is in operation, the running compressor will 

produce heat. This is normal and may potentially raise the room 
temperature. 

7.  When the product is defrosting, related indicating light will illuminate. 

 

DRAINAGE INSTRUCTION 

Switch off before carrying out any of these operations and leave for 3 minutes 
before switching on again. The extracted water is collected by the water tank 
(set up as supplied), or can be set up to drain continuously using a PVC hose 
(not included) connected to a water outlet tube , the drain point must be lower 
than the unit outlet (see details below). 

 

USE OF WATER TANK: 

When the tank full LED illuminates the tank is full, the 
compressor and the fan will stop operation, please 
empty the water tank. Remove the water tank: 

Remove the water tank as per Fig 01 and empty it. 
Gently refit the water tank into the unit in its original 
position.  

 

CONTINUOUS DRAINAGE 

If you want to use this function, please pull out the water tank and plug a 9mm 

internal diameter water pipe onto the “Water out 

tube” (See Fig.02).Replace the water tank into the 
unit, the unit will now operate while discharging the 
extracted water through the free end of the fitted 
pipe, Note, please ensure the free end is below the 
outlet connection.  

Please ensure drain away is lower than the unit 

outlet. 

 

Filter Removal 

  To remove the filter you must first remove 

the water tank as instructed above. 

  The filter can then be removed from its slot 

by gripping the filter handle and sliding it 
down and out of the back of the appliance 
as indicated below. 

  Every 2 weeks, remove the filter and clean 

it with warm water, below 40°C. Allow it to 
dry naturally and then replace by reversing 
the removal instruction above 

 

Care and Maintenance Instruction 

1.  To avoid the occurrence of vibration and noise the unit should not be 

operated while located on any soft or uneven surface. 

2.  Never insert any foreign objects into the unit through its air inlet or outlet to 

avoid hazard or unit failure. 

3.  During power off or when not in use for a long time, please disconnect the 

product from the mains. 

 

 

 

4.  For a better dehumidifying effect, the areas in the front and rear of the 

unit should be clear and free from any obstacles which will block the air 

flow of the unit. Do not block any air inlet or outlet grilles – keep clear of 

hanging drapes, curtains and furnishings- 

DO NOT COVER.

Fig 01 

Fig 02 