Dimplex DPRC26ECO-A Скачать руководство пользователя страница 4

4

NB:

 These symbols on your device mean:

•   This appliance is filled with Propane gas R290. Follow strictly the manufacturer's 

instruction concerning use and repairs!

•   Before using this appliance, you must carefully read the entire instruction 

manual.

•   Do not install, operate or store the device in a room with a floor area smaller 

than 13m

2

.

•   Repairs must be performed based on the recommendations from the 

manufacturing company.

•  Note also the information presented on the appliance.

•   Do not use means to accelerate the defrosting process or to clean, other than 

those recommended by the manufacturer.

•   The appliance shall NOT be stored in a room with continuously operating 

ignition sources (for example: open flames, an operating gas appliance or an 

operating electric heater).

•  Do not pierce or burn.

•  Be aware that the refrigerants may not contain an odour.

•   The appliance should be installed, operated and stored in a room with a 

floor area according to the amount of refrigerant to be charged. For specific 

information on the type of gas and the amount, please refer to the relevant label 

on the unit itself. When there are differences between the label and the manual 

on the Min. room area description, the description on label shall prevail.

•  Compliance with national gas regulations shall be observed.

•  Keep ventilation openings clear of obstruction.

•   The appliance shall be stored so as to prevent mechanical damage from 

occurring.

•    A warning that the appliance shall be stored in a well-ventilated area where the 

room size corresponds to the room area as specified for operation.

•   Any person who is involved with working on or breaking into a refrigerant circuit 

should hold a current valid certificate from an industry-accredited assessment 

authority, which authorises their competence to handle refrigerants safely in 

accordance with an industry recognised assessment specification.

•   Servicing shall only be performed as recommended by the equipment 

manufacturer. Maintenance and repair requiring the assistance of other skilled 

personnel shall be carried out under the supervision of the person competent in 

the use of flammable refrigerants.

WARNING: For using R290 refrigerant. This symbol shows that
this appliance uses a flammable refrigerant. If the refrigerant 

is leaked and exposed to an external ignition source, there is a 

risk of fire.

CAUTION:  RISK OF FIRE/FLAMMABLE MATERIALS. THE APPLIANCE MUST BE 

INSTALLED, USED & STORED IN AN AREA THAT IS GREATER THAN 13m

2

.

15429_Dimplex DPRC26ECO-A Manual.indd   4

15429_Dimplex DPRC26ECO-A Manual.indd   4

7/09/20   4:33 PM

7/09/20   4:33 PM

Содержание DPRC26ECO-A

Страница 1: ...table Air Conditioner Model DPRC26ECO A For domestic household use only INSTRUCTION MANUAL 15429_Dimplex DPRC26ECO A Manual indd 1 15429_Dimplex DPRC26ECO A Manual indd 1 7 09 20 4 33 PM 7 09 20 4 33...

Страница 2: ...t place on soft unstable or non horizontal angled surfaces Never operate the appliance if a cable or connector has been damaged after appliance malfunction or if the appliance was dropped or is otherw...

Страница 3: ...witch off the unit and take the plug out of the socket If you are not using the unit Before you clean or carry out maintenance on the unit If a fault occurs In the event of an electrical storm Avoid e...

Страница 4: ...ption the description on label shall prevail Compliance with national gas regulations shall be observed Keep ventilation openings clear of obstruction The appliance shall be stored so as to prevent me...

Страница 5: ...e checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flammable atmospheres Ensure that the leak detection equipment being used i...

Страница 6: ...uate temporary solution shall be used This shall be reported to the owner of the equipment so all parties are advised Initial safety checks shall include That capacitors are discharged this shall be d...

Страница 7: ...able for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe work If a leak is suspecte...

Страница 8: ...em electrically c Before attempting the procedure ensure that Mechanical handling equipment is available if required for handling refrigerant cylinders All personal protective equipment is available a...

Страница 9: ...hall be available and in good working order Hoses shall be complete with leak free disconnect couplings and in good condition Before using the recovery machine check that it is in satisfactory working...

Страница 10: ...s High Capacity in a compact size with fan cooling heating and dehumidifying function Temperature setting and display LED Digital display Electronic control with built in timer sleep mode Self evapora...

Страница 11: ...e see the real product for detailed information UNPACKING Unpack the carton and take the appliance and accessories out Check the device after unpacking for any damage or scratches on it Accessories 1...

Страница 12: ...gisters stoves or other products that products that produce heat Direct sunlight Mechanical vibration or shock Excessive dust Lack of ventilation such as cabinet or bookcase Uneven surface WARNING Ins...

Страница 13: ...duct tape if required It is recommended that the gap between the adapter and the sides of the window should be sealed off for maximum efficiency Step 5 Attach the hose connector to the exhaust air ou...

Страница 14: ...ature or timer setting 5 Up Press to Increase the desired temperature or timer setting 6 TIMER Press to set a time for the unit to automatically start or stop 7 SLEEP Press to turn sleep mode on or of...

Страница 15: ...d temperature 2 Heating your room Optional for Heating Function Unit only Press MODE button repeatedly until the LED of HEAT operation lights up Press UP DOWN button to set the temperature higher than...

Страница 16: ...es in the cooling operation or drying operation and the ambient temperature sensor senses the evaporator coil temperature is below 1 C then the compressor will stop operating for 10 minutes or until t...

Страница 17: ...nit before operating Remove the plug of the water outlet opening and keep it in safe area Securely and properly connect the drain hose and make sure it is not kinked and clear of obstruction Place the...

Страница 18: ...unit and unplug the power cord 2 Remove the filter mesh from the unit 3 Use a vacuum cleaner to suck dust from the filter 4 Turn the filter over and rinse the air filter under running water Let the wa...

Страница 19: ...olate and ventilate area 5 Do not get in eyes on skin or on clothing Do not breathe vapors or gas 6 Prevent entry to sewers and public waters 7 Stop the source of the release if safe to do so Consider...

Страница 20: ...s securely attached Water Leakage Overflow while moving the unit Empty the water tank before transport Check if the drain hose is kinked or bends Straighten the hose to avoid a trap existing Excessive...

Страница 21: ...rving the machine in ventilating dry non corrosive gas and safe place indoor ATTENTION The evaporator inside the machine has to be dried out before the unit is packed to avoid component damage and mol...

Страница 22: ...22 15429_Dimplex DPRC26ECO A Manual indd 22 15429_Dimplex DPRC26ECO A Manual indd 22 7 09 20 4 33 PM 7 09 20 4 33 PM...

Страница 23: ...3179 Victoria Australia Ph 1300 556 816 Glen Dimplex New Zealand Ltd 38 Harris Road East Tamaki Auckland 2013 New Zealand Ph 0800 666 2824 Maintenance Warranty Recycling Do not dispose of electrical...

Страница 24: ...co nz www dimplex co nz Glen Dimplex New Zealand Ltd All rights reserved Material contained in this publication may not be reproduced in whole or in part without prior permission in writing of Glen Di...

Отзывы: