background image

Service Manual

Model

DLGM29

Part Number

6908550000

7400620000R01

In keeping with our policy of continuous product development, we reserve the right to make changes without notice.
© 2013 Dimplex North America Limited

Dimplex North America Limited

1367 Industrial Road   Cambridge ON Canada N1R 7G8
1-888-346-7539   www.dimplex.com

REV PCN

DATE

00

-

30-AUG-12

01

-

6-Aug-13

IMPORTANT SAFETY INFORMATION

: Always read this manual first before attempting to service this log grate. For your 

safety, always comply with all warnings and safety instructions contained in this manual to prevent personal injury or prop-

erty damage.

Содержание DLGM29

Страница 1: ...Limited Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N1R 7G8 1 888 346 7539 www dimplex com REV PCN DATE 00 30 AUG 12 01 6 Aug 13 IMPORTANT SAFETY INFORMATION Always read th...

Страница 2: ...followed will result in damage to the equipment WARNING Procedures and techniques which if not carefully followed will expose the user to the risk of fire serious injury or death OPERATION 3 MAINTENA...

Страница 3: ...requency designation is indicated on the back of the remote control NOTE Before attempting any operation with the remote control pull the plastic insulator strip out from between the remote casing and...

Страница 4: ...each of the components directly up Figure 3 NOTE There are tabs on each end that need to be turned to release the components CAUTION It is strongly recommended that Distilled water or softened water b...

Страница 5: ...0740300RP 8 Metal Light Shield 1025340159RP 9 Light Shield Log 0441260100RP 10 Heating Assembly 9600520100RP 11 LED Light Assembly 3001100200RP 12 Removable Refill Container with Cap 0441440100RP 13 C...

Страница 6: ...6 www dimplex com WIRING DIAGRAM M 1 2 3 7 20 8 21 LOG 6 1 2 3 4 1 2 3 4 LOG 5 LOG 4 LOG 3 LOG 2 LOG 1 TRANSDUCER 24 VDC FAN MOTOR ELEMENT PCB EMBERBED...

Страница 7: ...s Required Philips head screwdriver Flat Head Screwdriver WARNING Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons NOTE Ensure that all of t...

Страница 8: ...isconnect and remove all of the logs from the unit including the light shield and associated log and put them in a safe place Figure 5 2 Remove the removable refill container and set aside 3 From the...

Страница 9: ...eplace Remote Control Receiver Initialize to Remote Control All logs dim not glowing Loose connection Check wiring connections Defective Log Grate wiring Replace Log Grate Assembly One Log dim not glo...

Страница 10: ...to be falling Loose connection Check heater wiring connections Defective Heater Replace Heating assembly Mist does not appear to be com ing out evenly Unit is not level Level unit Log arrangement is b...